Revised Panelboards 06/28/16

Transcription

Revised 06/28/16PanelboardsPANELBOARDS11Type P4 PanelboardsGeneral FeaturesMain Lug / Main BreakerThe P4 panel is a medium sized footprintdistribution panel to fit a large number ofapplications that require more or largerbranch devices and higher amp ratingsthan the lighting panel class offers. Evenwith the increased capacity, this panel isa space saver with its 32" width and 10"depth. The P4 panel offers a wide arrayof factory-assembled options and hasthe ability to mix breaker frames in unitspace up to 800 amps and fusibleswitches up to 200 amps. Bussingoptions for the P4 vary from the standardtemperature rated aluminum totemperature rated copper and 750A/SIaluminum and 1000A/SI copper designs.All aluminum bussing in the P4 panel istin-plated as a standard. Silver-plated isoffered as the default for copper bus andtin as an option. Integrated time clocks,bus mounted contactors as mains orsubmains, split bus and subfeed lugs (upto 600 amp) are just a few of the optionsof this flexible panel.The 3 panel configurations defined bythe unit space allowed for a givenamperage, main device and box height.The P4 panel starts with a 60" high box.All of the branch devices are unit spacemounted. Breakers and switches can bemixed and matched to meet customerrequirements.Enclosure – Standard Type 1 enclosureis 32" wide x 10" deep. X Box Height isdetermined by main device and unitspace. See charts for box height.Voltage – 600V AC max.250V DC max.Amperage – 400-800 amp main breakeror 400-1200 amp main lug only.Short Circuit Rating – 200 KAIC max.symmetrical or equal to the lowest rateddevice installed unless a series rating isindicated. Panels with subfeed orfeed-thru lugs without a main device,circuit breaker or fusible unit, are limitedto a three-cycle rating. The three-cyclerating for the P4 panel is limited to 42KAIC. Note that the main device maybe mounted remote from the panel.Bussing – The P4 panel has moreoptions to meet market requirements.The standard bussing is temperaturerated aluminum. The rating is per therequirements of UL 67 – the standard forpanelboards. All aluminum bussing istin-plated. Optional bussing for the P4panel is: 750 A/SI aluminum, temperaturerated copper, and 1000 A/SI copper.The copper bus option for this panelis silver-plated.Weight – ApproximateTotal panelboard weight when filledwith a normal quantityof breakers and accessories is about 8lbs. (1 kg) per inch(54g per mm) of box height.Main Lugs 1Ampere Rating400(1) - #3/0 AWG-500 kcmil(2) - #3/0 AWG-250 kcmil(2) - #3/0 AWG-500 kcmil(3) - #3/0 AWG-500 kcmil(4) - #3/0 AWG-500 kcmil(4) - #3/0 AWG-500 kcmil60080010001200aConnectors Suitable forCopper or Aluminum lternate lugs for 750 kcmil cable are available, butAresult in significant loss of branch unit mounting space.Consult Siemens.Gauge Steel of BoxesFronts, Surface and FlushDimensions ininches (mm)Gauge SteelWidthHeightBox60 - 75 - 90(1524, 1905,2286)#161 #14 (1 piece trim)#14 Ga (4 piecetrim)#12#12 (1 piece trim,door in door)#10#10 (1 piece doortrim in)#16#16 (4 piece trim)32"(813)a BoxFrontshas 16 gauge side panels, 14 gauge backplates and12 gauge back support. Enclosure SelectionAvailable Circuit Space in Inches (mm)Enclosure Dimension in Inches (mm)Dimension “C”HWDMain LugMain BreakerType 1 and Type 3R/12400-800A400-800A60 (1524)75 (1905)90 (2286)32 (813)32 (813)32 (813)10 (254)10 (254)10 (254)30 (762)45 (1143)60 (1524)21.25 (540)36.25 (921)51.25 (1302)Main Breaker Unit Space nsions in Inches (mm)400JXD6, JD6, HJXD6,HJD6,HHJXD6, HHJD6NJ, HJ, LJ SJD6, SHJD6CJD6, SCJD6LXD6, LD6, HLXD6,HLD6, HHLXD6, HHLD6NL, HL, LL SLD6, SHLD6CLD6, SCLD6NM, HM, LMSentron10.425 (265)VLSentronSentronSentron12.500 (318)10.425 (265)8.250 (210)10.425 (265)VLSentronSentronVL11.250 (286)10.425 (265)8.250 (210)10.500 (267)400400400600600600600800AB13.125 (333) a Standard trim is four piece without door. Surface or flush one piece trim is available for32 in. (813 mm) wide circuit breaker panel.Solid state (electronic) trip units only.11-50Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog

PanelboardsType P4 PanelboardsDimensions ectronic(Solid (Solid state)SentronThermalMagneticVLElectronic(Solid state)VL800FrameTypeJXD6, JD6HJXD6, HJD6HHJXD6, HHJD6CJD6NJHJLJSJD6SHJD6SCJD6LXD6LD6HLXD6, HLD6HHLXD6, HHLD6CLD6NLHLLLSLD6SHLD6SCLD6NMHMLMNMHMLMMaximum Interruption Rating 25,00035,00050,00025,00035,00050,000Unit SpaceRequirements inInches (mm)8.75 (222)8.75 (222)8.75 (222)8.75 (222)6.25 (159)6.25 (159)6.25 (159)8.75 (222)8.75 (222)8.75 (222)8.75 (222)8.75 (222)8.75 (222)8.75 (222)8.75 (222)6.25 (159)6.25 (159)6.25 (159)8.75 (222)8.75 (222)8.75 (222)8.75 (222)8.75 (222)8.75 (222)8.75 (222)8.75 (222)8.75 (222)Trip Amperage200, 225, 250, 300,200, 225, 250, 300,200, 225, 250, 300,200, 225, 250, 300,250, 400250, 400250, 400200, 300, 400200, 300, 400200, 300, 400450, 500, 600250, 300, 350, 400,250, 300, 350, 400,250, 300, 350, 400,250, 300, 350, 400,400, 600400, 600400, 600300, 400, 500, 600300, 400, 500, 600300, 400, 500, 600600, 700, 800600, 700, 800600, 700, 800600, 800600, 800600, ,500,500,500,PANELBOARDSAmpereRating11Main Breaker Selection600600600600Main Lugs Only Wire Bending ndardw/Feed-thruDimensions in inches (mm)Main 64)15.969———(406)16.750———(419)Main Lugs Only Unit SpaceBranch Switch Unit SpaceMounting Height in inches (mm)AmpereNumberTwinRatingof PolesMounted30-302, 32.50 ,2,2,2,2,32,2,3333333333335.00 (127)5.00 (127)5.00 (127)7.50 (191)7.50 (191)10.00 (254)——7.5 (191)7.5 (191)7.5 (191)7.5 (191)7.5 (191)10.00 )ACVoltageCables PerConnectorConnectors Suitable forCopper or 60060060011111111211111111#14 - #8 AWG (Cu Only)#14 - #4 AWG#14 - #4 AWG#14 - #4 AWG#10 - #1/0 AWG#10 - #1/0 AWG#6 AWG - 350 kcmil#6 AWG - 350 kcmil#6 AWG - 350 kcmil#14 - #8 AWG#14 - #4 AWG#14 - #4 AWG#10-#1/0 AWG#10-#1/0 AWG#6 AWG - 250 kcmil#10-#1/0 AWG#6 AWG - 250 kcmilSiemens Industry, Inc. SPEEDFAX 2011 Product Catalog11-51

Revised 02/15/16PanelboardsPANELBOARDS11Type P4 PanelboardsDimensions Branch Breaker Side Gutter Inches (mm)ReferenceLetterPanel Width 32 InchesDimensions in inches (mm)ABCDEFHIJKLMNOPQRST11.0 (279)10.98 (279)8.62 (219)7.0 (178)5.75 (146)5.25 (133)4.62 (177)8.76 (223)10.42 (265)10.0 (254)8.25 (210)10.0 (254)7.0 (178)5.0 (127)7.50 (191)7.9 (200)7.9 (200)2.5 (318)11.25 (286)ABCDHEFQRIJLSTKMBL, BLH, HBL, BQD, BLE, BLEH, BL, BLH, HBL, BQD, BLE, BLEH,BLR, BLF2, BLHF2, HBLF2,BLFB, BLR, BLF2, BLHF2, HBLF2, BLFB,BLHFB, BAF, BAHF, BGL, BQDBLHFB, BAF, BAHF, BGL, BQDNGB, HGB, LGBNGB, HGB, LGBNEB, HEBNEB, HEBED4, ED6,ED4, ED6,HED4HED4CEDCEDQJ2, QJH2, QJ2H,QJ2, QJH2, QJ2H,QR2, QRH2, HQR2, HQR2HQR2, QRH2, HQR2, HQR2HFXD6, FD6, HFXD6,FXD6, FD6, HFXD6,HFD6, HHFXD6, HHFD6,HFD6, HHFXD6, HHFD6SFD6, SHFD6SFD6, SHFD6ND, HD, LDND, HD, LDNF, HF, LFNF, HF, LFCFD6, SCFD6JD6, JXD6, SJD6, HJD6, HXJD6, SHJD6, HHJD6,HHJXD6, LD6, LXD6, SLD6, HLD6, HXLD6, SHLD6,HHLD6, HHLXD6CJD6, SCJD6, CLD6, SCLD6NJ, HJ, LJNL, HL, LLNM, HM, LMVB 30A, VB 60A (5”)VB 30A, VB 60A (5”)BCDHEFQRIJLSTKMNVB 30A, VB 60A (5”)VB 30A, VB 60A (5”)NOVB 100 - 200AVB 100 - 200AOP11-52ASiemens Industry, Inc. SPEEDFAX 2011 Product CatalogVB 100 - 200A SingleP

Revised 01/14/16PanelboardsPower and DistributionSelection Replace fifth and sixth positionin panelboard catalog number,with alternate main breaker code.Use price adders from main breakersection table. Horizontally mounted.Main Lugs Only — shown with aluminum bus, top fed, and surface trims.MaximumPanel Amps40060080010001200MaximumPanel 560304560304560208Y/120V3-Phase, 4-WireCatalog S240V3-Phase, 3-WireCatalog S240/120V3-Phase, 4-WireCatalog S480Y/277V3-Phase, 4-WireCatalog S120/240V or 250 V DC Max1-Phase, 3-WireCatalog S480V a3-Phase, 3-WireCatalog SMain Circuit Breaker — shown with standard mains, aluminum bus, top fed, and surface trims.MaximumPanel Amps400600800MaximumPanel ase, 4-WireCatalog 75M1800ATSP4C90M1800ATS240V3-Phase, 3-WireCatalog 75M1800ATSP4D90M1800ATS240/120V3-Phase, 4-WireCatalog 75M1800ATSP4B90M1800ATS480Y/277V3-Phase, 4-WireCatalog 75M1800ATSP4E90M1800ATS120/240V or 250 Vdc Max1-Phase, 3-WireCatalog 75M1800ATSP4A90M1800ATS480V a3-Phase, 3-WireCatalog 75M1800ATSP4F90M1800ATS a For600V application, change “F” in position 3 to “G”. See alternatemain breaker table on page 11-54 for 600V rated mains. Change position5 and 6 and add price from table. Price only 600V rated branch breakers.Product Category PBSBSiemens Industry, Inc. SPEEDFAX 2011 Product Catalog11-53PANELBOARDSShown with Standard Mains, Top Fed and Surface TrimCatalog number is for aluminum mainPanels are top feed, surface mounted.bus. For optional copper main busFor bottom feed, change “T” in positionchange “A” in position 11 to “E” (silver12 to “B”. For flush mounting,plated copper bus).change “S” in position 13 to “F”.11Type P4

PanelboardsPANELBOARDS11Power and DistributionSelection Type P4Alternate Main Breaker lidstate)VLFrameTypeAlternateMain 00800800Maximum InterruptionUnit SpaceRequirements Rating (KAIC) Volts ACin 25,00050,00050,00025,00035,00050,000For inches / millimeters conversion, see Application Datasection.11-54Siemens Industry, Inc. SPEEDFAX 2011 Product CatalogProduct Category PBSB

Revised 11/10/15PanelboardsPower and DistributionSelection neralApplication150Electronic(Solid lMagneticSentronElectronic(Solid id state)ThermalMagnetic600Electronic(Solid LElectronic(Solid state)VLa Space FCH-AFCINGBHGBLGBNEBHEBED4HED4 CED6NDHDLDQJ2QJH2QJ2HQR2QRH2HQR2HQR2HFXD6, FD6HFXD6, HFD6HHFXD6, HHFD6CFD6NFHFLFJXD6, JD6HJXD6, HJD6HHJXD6, HHJD6CJD6NJHJLJSJD6SHJD6SCJD6LXD6LD6HLXD6, HLD6HHLXD6, HHLD6CLD6NLHLLLSLD6SHLD6SCLD6NMHMLMNMHMLMprice covers cost of housing frame plate withblank cover plate. Provision price includes all necessarymounting hardware, less circuit breaker, and includeshousing frame cover plate with breaker handle opening.Product Category PBSBPoles1, 2, 321, 2, 31, 2, 31, 2, 31, 2, 31, 22, 31, 21, 21, 21, 21, 21, 21, 21, 21, 2, 31, 2, 31, 2, 31, 2, 31, 2, 31, 2, 31, 2, 32, 33332, 32, 32, 32, 32, 32, 32, 32, 32, 32, 333332, 32, 32, 333333332, 32, 32, 32, 333333332, 32, 32, 3333b 1TripAmperage15-60, 70, 80, 90, 100, 110, 12515, 20, 30, 40, 50, 60, 70, 80, 90, 10015-60, 70, 80, 90, 100, 110, 12515-60, 70, 80, 90, 100, 110, 12515-50, 60, 70, 80, 90, 10015-50, 60, 7015, 20, 3015, 20, 3015, 20, 30, 40, 50, 6015, 20, 30, 40, 50, 6015, 20, 30, 40, 50, 6015, 20, 30, 40, 50, 6015, 2015, 2015, 2015, 2015-60, 70, 80, 90, 100, 110, 12515-60, 70, 80, 90, 100, 110, 12515-60, 70, 80, 90, 100, 110, 12515-60, 70, 80, 90, 100, 110, 12515-60, 70, 80, 90, 100, 110, 12515-50, 60, 70, 80, 90, 100, 110, 12515-50, 60, 70, 80, 90, 100, 110, 12515-50, 60, 70, 80, 90, 100, 110, 12560, 100, 15060, 100, 15060, 100, 15060-110, 125, 150, 175, 200, 22560-110, 125, 150, 175, 200, 22560-110, 125, 150, 175, 200, 225100, 110, 125, 150, 175, 200, 225100, 110, 125, 150, 175, 200, 225100, 110, 125, 150, 175, 200, 225100, 110, 125, 150, 175, 200, 22570-110, 125, 150, 175, 200, 225, 25070-110, 125, 150, 175, 200, 225, 25070-110, 125, 150, 175, 200, 225, 25070-110, 125, 150, 175, 200, 225, 250100, 150, 250100, 150, 250100, 150, 250200, 225, 250, 300, 350, 400200, 225, 250, 300, 350, 400200, 225, 250, 300, 350, 400200, 225, 250, 300, 350, 400250, 400250, 400250, 400200, 300, 400200, 300, 400200, 300, 400450, 500, 600250, 300, 350, 400, 450, 500, 600250, 300, 350, 400, 450, 500, 600250, 300, 350, 400, 450, 500, 600250, 300, 350, 400, 450, 500, 600400, 600400, 600400, 600300, 400, 500, 600300, 400, 500, 600300, 400, 500, 600600, 700, 800600, 700, 800600, 700, 800600, 800600, 800600, 800Unit SpaceRequirementsin InchesSingle Twin—3.75 —3.75 —3.75 —3.75 —3.75 —3.75 —3.75 —3.75 —3.75 —3.75 —3.75 —3.75 —3.75 —3.75 —3.75 —3.75 —3.75 —3.75 —3.75 —3.75 —3.75 —3.75 —3.75 —3.75 8.75—8.75—to 6 poles may be mounted in 3.75" of unit space.such as shunt trips on three pole breakersrequire 6.25" of unit space.c AccessoriesMaximum Interruption Rating (KAIC)Volts 0010,000————— 100,00025,000—14,000—— 100,00035,000—14,000—— ��— �� 100,000—42,000——— 200,000— 200,000— 100,000—65,000—35,000—18,000— 100,000—65,000—20,000— 200,000— —25,000—————65,000————— 100,000—————65,000—35,000—22,000— 100,000—65,000—25,000— 200,000— 100,000—25,000— 200,000— 200,000— 100,000—65,000—35,000—18,000— 100,000—65,000—20,000— 200,000— 100,000—25,000—65,000—35,000—25,000— 100,000—65,000—35,000— 200,000— 100,000—50,000— 200,000— 150,000— 100,000—65,000—35,000—25,000— 100,000—65,000—25,000— 200,000— 100,000—25,000—65,000—35,000—25,000— 100,000—65,000—35,000— 200,000— 150,000— 00—25,000— 100,000—65,000—35,000— 200,000— 100,000—50,000— 200,000— 150,000— 100,000—65,000—35,000—25,000— 100,000—65,000—25,000— 200,000— 100,000—25,000—65,000—35,000—25,000— 100,000—65,000—35,000— 200,000— 150,000— 100,000—65,000—35,000—25,000— 100,000—65,000—35,000— 200,000— 100,000—50,000—65,000—35,000—25,000— 100,000—65,000—35,000— 200,000— 100,000—50,000d HED4e HED1-pole 15–30A 65,000 IR35–100A 25,000 IR4 3-Pole 42,000 IRSiemens Industry, Inc. SPEEDFAX 2011 Product Catalog11-55PANELBOARDSBreakerFrameRating11Branch Breaker Selection

Revised 06/28/16PanelboardsPANELBOARDS11Power and DistributionSelection Branch Switch SelectionAmpereRatingAmpereRatingMountingHeight (inches)240V — Twin MountedNEC Fuse Clips b30-3030-3030-6060-6060-100100-100200-200600V — Twin Mounted5557½7½10NEC Fuse Clips b3060100200200NEC Fuse Clips b30-3030-6060-6060-100100-100200-2002½c240V — Single MountedMountingHeight (inches)7½7½7½7½7½10600V — Single MountedNEC Fuse Clips b1002007½7½7½107½7½10Blank Plates — CircuitBreaker and Vacu-BreakFor use with Type P4, Type S4 or Sentron SPP Shallowdepth panelboardsType S4/P4/SPP (10" deep)and F1/P4/FPP (10" deep)Height(inches)Connecting Strap Kits — w/o Circuit BreakerFor use with Type P4, Type S4 or Sentron SPP Shallow depth milyBreakerTypeCatalogNumber ronVLSentronBL, BQDNGB, HGB, LGBEBEDCEDDGQJQR 6FPB023.756FPB035.06FPB0510.06FPB10Filler PlatesFor use with Type P4, Type S4 or Sentron SPP Shallowdepth panelboardsFiller PlateCatalog NumberBreaker TypeBL, BLH, HBLED2, ED4, ED6HED4, NGB, HGB, LGBDFFP1eNEB, HEBEBF1Connecting Strap Kits dFusibleFor use with Sentron Shallow Depth or TypeSPP/FPP/F1/P4 power panelsUnitHeight(inches)10" Deep Box30–302.5F60230–605, 7.5F65730–605, 7.5F65760–605, 7.5F657For use with Sentron Shallow Depth orType SPP/FPP/F1/P4 power panels60–1005, 7.5F657100–1005, 7.5F657Breaker 0800Cover PlatesQRCatalog NumberSQRC AmpereRatingCatalog NumberFor inches / millimeters conversion, see Application Data section.a Includeshousing frame plate without breaker handleopening. Provisions include all necessary mountinghardware less breakers.b For Class J, R or T fuse clip prices, refer to page 11-57.For Class J fuse clips price 600V, 71 2" high units.11-56c NEC To Suitablefuse clips only.stock item.to replace QF3 in P1 thru P5 Panelboards andSwitchboards. Althoughd NormalSiemens Industry, Inc. SPEEDFAX 2011 Product Catalogreplace a QJ with a QR only a new cover is neededup to 225AQR is rated 250A, it is limited to 225A inpanelboard.Product Category PBSB

Revised 01/15/16PanelboardsModifications and AdditionsSelectionDescriptionOne piece front with doorHinged Gutter Covers 4 pc frontToggle Switch — SPST or 3-way15A, 277V maximumPilot Light — General PurposeNeon or IncandescentPushbuttonIncreased Capacity NeutralAmpere RatingPhaseNeutralUnit Space( inches)400400600800600800120012000000Fuse Clip Provisions(Add to 250 Volts or 600 VoltsUnit Prices Per Switch)AmpRating30601002004006008001200Unit Spaces(Additional inches)MLO00N/AN/AClassT Lugs – For Main Lug Only PanelsStandard main lugs and neutral lugsare tin-plated aluminum, UL listed foruse with aluminum/copper cables.Copper only lugs are an option.Spanner Wrenches(for Vacu-Break Switches)Ampere Rating400 - 1200Ground Fault on Main BreakerShunt Trip on Main and Branches DescriptionConventional Ground Faultground fault relay, ground sensor, CPT& shunt tripTest and Monitor Panel Includes:DescriptionBL, BQD, NGB, HGB, LGB (branch only)QJ2, QJH2, QJ2H, QR2, QRH2, HQR2,HQR2H, NEB, HEB, ED4, ED6, HED4,HHED6, CED6Ground Fault add toSensitrip III breaker priceAll others to 800ATime Clocks Sangamo, Tork or Paragon time clockcan be supplied, mounted in panelboardcabinet. For required increase in enclosuredimension, consult local sales office.100% Rated Main Circuit BreakersAmpereRating400ADescriptionTime clock (1- or 2-Pole, Single orDouble Throw Contacts; 3-Pole SingleThrow)277V Maximum with Plain DialOptional:Astronomical DialAn Omitting DeviceReserve Power or CarryoverFeed-Thru LugsAmpere RatingUnit Space (inches)4006008001200ClassRSubfeed or Feed-Thru Lugs(One Set Per Panel)Subfeed Double Lugs(Main Lug Panels)AmpRatingClassJMain BusStandard main bus and ground bus aretin-plated aluminum. For copper mainbus, neutral bus and ground bus, addfrom the table for each panel.101017.517.5Grounding of Panelboards GroundBars (except for brazed-to-box)are shipped with the panel interiorfactory mounted. Non-Insulated Equipment GroundBar – Standard Copper Non-Insulated Ground Bar Al Insulated Equipment Ground Bar Cu Insulated Equipment Ground Bar Ground Bar Brazed to Box Availablein 90” high enclosure only. Unit space is 421/2” with Test and Monitor Panel; 45” without Test andMonitor Panel.Product Category PBSB600ABreakerTypeJXD6H, HJXD6HSCJD6H, SHJD6HNJY, HJY, LJYLXD6H, HLXD6HNMY , HMY , LMY Space and Mounting Provisions OnlyCircuit Breaker AccessoriesHandle Blocking DeviceBlocks handle in either the“ON” or “OFF” position.Padlocking Device – Padlocksin “OFF” position. Not available on Sensitrip III.For required unit space, consult local sales office.Shunt Trip on 100A frame breakers increases mounting height to 6.25” for twin mounting. The 600A, 100% rated breaker requires the use of an800A frame breaker.Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog11-57PANELBOARDSDevices Mounted on Gutter CoverIncludes Device, Mounting – Wired orUnwired11P4 Panelboards

Revised 09/19/14PanelboardsPANELBOARDS11Embedded Micro Metering Module Selection SEM3 System configured in PanelboardsThe Siemens SEM3 system can be configured for factoryinstallation in branch circuit monitoring applications using theSiemens COMPAS configuration tool. This option can lowerthe installation time of the system for the installer while providing a factory warrantied solution.The SEM3 system can be factory installed in unit space intype P2, P4, & P5 Siemens panel boards. Please note P1 andP3 configurations are not available at this time and the amountof unit space needed varies depending upon the application.Please note that lead time adders will apply and may varydepending upon the configuration of the system.SEM3 for use in Siemens PanelboardsAvailable in a NEMA 1, 3R, or 12 rated enclosureControllerSEM3 controller is mounted in unit space opposite of the feed location specified in COMPAS(i.e., bottom mount for top feed) and will require 3” of unit space. Each controller will be powered by direct tap connection to the panel section bus. Each controller can monitor up to 45circuits. Applications that require monitoring more than 45 circuits will require additional controllers.Current Transformers (CTs)Five sizes of CTs are available for use in the P2 panel: 50, 125, 250, 400 & 600 amp. All CTsare pre-mounted to a support bracket that attaches to the base rail of the interior of the panelboard. Each bracket supports a maximum of 3 CTs and is designed for the breaker selected(brackets are not interchangeable between breaker frames). Each CT will be attached to a datamodule that is placed in the meter racks.Meter RacksEach meter rack requires 3” of unit space. All meter racks will be installed next to the SEM3controller in unit space. The COMPAS configuration tool will select the appropriate meter rackconfiguration according to the user’s application and will use the 21 space meter rack as adefault option where possible. Only one meter rack (regardless of number of positions) can beinstalled in 3” of unit space.NOTE: Monitoring of 45 circuits will require 9" of unit space: two 21 position racks and one 3position rackOther ConsiderationsConfiguration: Data modules from CTs monitoring a circuit breaker must be mounted adjacent to one another in the meter rack. Any field changes to the factory configuration must takethis into account.Start-up & Commissioning: Siemens can provide these services. Contact your localSIEMENS PDS Power Solutions Business Developer for more details.Billing Services for sub billing applications: Billing services are available. Contact your localSIEMENS PDS Power Solutions Business Developer for more details.11-58Siemens Industry, Inc. SPEEDFAX 2011 Product CatalogProduct Category PBSB

Panelboards Revised 09/19/14Embedded Micro Metering Module Enclosure heights are in 15" increments from 60" thru 90".Enclosure heights: 60", 75", 90" (there are optional depths also)The COMPAS configuration tool can provide actual dimensionsbased on the configuration. Example below is largest standardP4 enclosure for factory assembled panel - unit space is in 3.75"increments - up to 6 circuits can occupy each 3.75" of unit space.32" std. width for P4Main Breaker / Main Lug spacevaries based on selected optionsUnit space variesbased on selected optionsNote: All circuits do not have to be monitoredby SEM3 - user can select any circuits in thisspace to be monitored.Based on smallest branch breakers and a 3-phase mainbeing monitored. There is a maximum of 63 circuits that canbe monitored with the configuration shown. Someselections of main breakers and other subfeed options couldlimit this further.In this situation there is 37.5" of unit space available so 60 branch circuits could be monitored.If monitoring the main three additional circuits couldbe monitored with a total of 63 circuits.This requires two controllers and three 21 positionracks using 18.75" of unit space.- see below -SEM3 space varies by number of circuitsmonitored - this uses unit space. 7.5" of space for up to 21 circuits monitoredone controller and one 21-pos rack 11.25" of space for up to 42 circuits monitoredone controller and two 21-pos racks 15" of space for up to 45 circuits monitoredone controller and two 21-pos racks plus one 3-pos rack 18.75" of space for up to 63 circuits monitoredtwo controllers and three 21-pos racksNote: If subfeed space is needed - it will takeaway from available unit space.Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog11-59PANELBOARDSExample P4 Panel with SEM3 Type 1 EnclosureP4 (32" Wide x 10" Deep)11P4 DevicesEnclosure sizesSelection

Revised 08/17/15PanelboardsPANELBOARDS11Modifications and AdditionsSelectionLug ModificationsCompression LugsStyleAmpRatingBreaker TypeCompression ConnectorsAvailable Unit Space ReductionMLO400600800N/AN/AN/AAll compression lugsAll compression lugsAll compression lugsDeduct 5.0” of Unit Space1000N/AAll compression lugs1200N/AJD6, JXD6, HJD6, HJXD6,HHJD6, HHJXD6, CJD6,SJD6, SHJD6, SCJD6LD6, LXD6, HLD6, HLXD6,NL, HL, LLHHLD6, HHLXD6,

device installed unless a series rating is indicated. Panels with subfeed or feed-thru lugs without a main device, circuit breaker or fusible unit, are limited to a three-cycle rating. The three-cycle rating for the P4 panel is limited to 42 . SHJD6 Sentron 10.425 (265) 400 CJD6, SCJD6 Sentron 8.250 (210)