OSSEOINTEGRATED FIXTURESProduct CatalogueVersion 8

Southern Implants is a leading provider of unique and innovative dental implant products with a focus on top-endprofessional users who want more choices. Southern's expertise in research, development and manufacturing of dentalimplants allows us to provide Innovative Treatment Solutions that will reduce treatment times and improve patientoutcomes.Striving for excellence and meeting customer needs, has led to our wide product range characterized by Unique andInnovative products which include;Multiple interfaces, to suit customer preference.INVERTATM implant, featuring a body-shift design, engineered for primary stability and suitable for immediateloading.Co-Axis , sub-crestal angle correcting implant, available in angulations of 12, 24 & 36 and various internal andexternal connections.MAX implant, specifically designed for immediate molar tooth replacement.The ZYGAN and ZYGEX implants for severely resorbed maxilla and craniofacial reconstruction.Our product portfolio is in synchronized evolution with protocol improvements and technological advances.My sincere thanks to all specialists, dentists and technicians who put their trust in our company.Graham BlackbeardManaging Director, Southern Implants02

CONTENTSExternal Hex Ultra-Short Ø3.75mm / Ø4.5mm ImplantImplants & Surgical Components.Page 06Prosthetic Flowchart.Page 07Page 07Prosthetic Flowchart: Magnetic Retention, Steco Titanmagnetics for IE.Page 08Site Preparation Sequence (Parallel walled & Tapered implants).Page 09Instrumentation (Parallel walled & Tapered implants).Surgical TrayI-EO-EG.Page 10Driver and Screw Information.Page 12Steco Titanmagnetics.Page 12Page 14Implant dimensions and Information.Page 15Explanation of Symbols.Further information available on our websiteSOUTHERNIMPLANTS.COM03

NOTE:04Images are for illustration purposes only and do not necessarily accurately represent the product.All dimensions in this catalogue are in mm, unless otherwise specified.Not all products are cleared for sale in all countries.

EXTERNAL HEXØ3.75mmØ4.5mmULTRA-SHORT05

Ø3.75mm Implants (Parallel Walled)3mmIE3Implants are available in lengths of:Implant dimensions and information - page 14CylindricalItem codeImplant lengths (in mm)IE3Surgical ComponentsHealing AbutmentsCover ScrewTBE8nSC4Ø4.58lengthØ3.75mm / Ø4.5mm Implants (Parallel Walled & Tapered)6mm4.1mm4mmIE4IET4IE64.1mmIETi4(Internal Drive)Implants are available in lengths of:Implant dimensions and information - page 14CylindricalTaperedItem codeImplant lengths (in mm)Item codeImplant lengths (in mm)IE4/6IET4IETi4Surgical ComponentsCover ScrewSCU206Healing /6/8lengths(Internal Drive)

Prosthetic RetainingScrewsSC4TBE8nIE3ABETC9GCP3(PICK-UP)1 SeriesScrewsSCU2TB3 / 4 / 5.5 / 7 / 8.5 / 10GoldTitaniumIE4WBIE6IET4IETi4Prosthetic FlowchartMagnetic Retention, Steco Titanmagnetics for IELaboratoryAnaloguesAbutmentsMagnetoX-Line (standard spherical 265U.00.02.X265KU.00.01.X265RU.00.01.X265Kfor silcone prostheseswith collarfor acrylic prostheseswith .Z315Kfor silcone prostheseswith collarfor acrylic prostheseswith collarOrbitaA.00.02.X2653.5 / 5 / 6.5 / 8Auricular / NasalZ-Line (wide spherical 02.01.Z800A.00.02.Z695M.00.01.Z1000IE44.75 / 6 / 7 / 8T-Line (Telescopic abutment)IE6I.02.01.T520I.02.01.T7205.2 / U.00.01.T570for silcone prosthesesfor acrylic prosthesesNOTE: See page 20-23 for more information on Steco TitanmagneticsØ prosthetics and instrumentation.07

Site Preparation SequenceØ3.75mm Parallel Walled (IE3)-IBSDTAPmØ3.0mmØ2DRB.0m-MSm.0mØ3.0mmDense BoneØ2DRB.0mm-MSMedium BoneØ2DRB-MSSoft Bone3mm lengthØ3.75mm Parallel Walled (IE4)-IBSDTAPmØ3.0mmØ2DRB.0m-MSm.0mØ3.0mmDense BoneØ2DRB.0mm-MSMedium BoneØ2DRB-MSSoft Bone4mm lengthØ3.75mm Parallel Walled (IE6)S4mm lengthm.0mØ4Ø2.0mmSD-RB-MmØ4.0mmDense Bone.0mØ2-MRBD-Ø2.0mmSMedium BoneS-MRBD--IBD-Ø4.0mm Tapered (IET4 / IETi4)Soft BoneTAPm.0m.0mØ3D-Ø2RBmS-MmØ3Ø2.0mmDense Bone.0m-MRBD-Ø2.0mmS-MRBSMedium BoneSoft BoneD-6mm lengthNOTE: The total implant length is reached when the flange of the 4mm tapered drill touches the bone surface. Drilling beyond this point may compromise primary stability of the implant.08

INSTRUMENTATIONFixture Mounted Implants (Parallel Walled & Tapered)Insertion ToolsIE3IE4Wrench ConvertersI-CON-XI-CONU-XI-WI-CSTI-WI-SHFixture MountDriver(With W&H)Fixture MountUniversal Driver(Without W&H)For Handpiece inserts(Latch-type)featuring the W&H hex.For HEXconnection offixture mountsIET4IE6Internal Drive Implant (Tapered)Ø4.5mm Tapered (IETi4)Wrench ConvertersInsertion ToolsIETi4I-HID-S / M / LI-HIDU-S / M / LI-WIID-S / LI-WI-CSTI-WI-SSHandpiece Insertwith W&HHandpiece InsertUniversalWrench InsertFor Handpiece inserts(Latch-type)featuring theW&H hex.For SQUAREconnection offixture mountsand instruments(Internal Drive)* Most instruments are available in various lengths09

INSTRUMENT TRAYI-EO-EG For surgical placement of Extraoral ImplantsBone TapPilot DrillD-RB-MSCover Screw Drivers(0.9mm)Ø2.0mmTwist DrillsFinalTwist DrillsD-20E-03FD-30E-03FI-CS-HD / onal)D-TAP-IBSI-HHD-09Handpiece InsertFinalTapered DrillD-40E-04FPLACEMENT TOOLSDRILLSDRIVERSIE3I-WI-09Wrench InsertIE40.9mm HexIE6Placement ToolsIETHex Drivers(1.22mm)I-CON-X / XSI-CONU-X / XSI-HD-S/M/LHandpiece InsertHandheldStandard Abutment Drivers(Hex)Drill ExtensionsI-HID-S / M / LI-ADHandheldInternal Drive,Handpiece InsertI-HHD-22S/M/LHandpiece InsertI-DE-GI-DE-KConverter(Optional)I-WI-C-S / LI-WIID-S / LI-HADHandpiece InsertInternal Drive,Wrench InsertI-WI-22S/M/LWrench InsertConvert latch type instrument,with the W&H hex to fit,with square connectionTorque wrench.I-WI-AWrench Insert10

Wrench ConvertersI-WI-CSTFor Handpiece inserts(Latch-type)featuring the W&H hex.I-WI-SLFlat SpannerFor Handpiece inserts(Latch-type)without the W&H hex.I-SP-X (System specific)I-WI-SSFor SQUAREconnection offixture mountsand instrumentsI-WI-SHFor HEXconnection offixture mountsWrenchTorque AttachmentsI-TWSI-TWS-B45I-TWS-B100NOTE:· The surgical kit has an intuitive layout to guide the surgeon through the drill sequence.Most Instruments available in Short / Medium / Long.All instruments and tooling used during the procedure must be maintained in good condition, and cleaned and sterilized prior to to use. Please consult the Southern ImplantsCleaning and Sterilization Procedure Guidelines (CAT-1039) for guidance concerning the maintenance of drills, instruments, and surgical trays.For Polishing Protector Caps refer to CAT-101011

DRIVER AND SCREW INFORMATIONAlternative DriversHex DriversHANDHELDHANDPIECEWRENCH1.22UNIVERSAL 1.22/1.271.22UNIVERSAL 1.22/1.271.22UNIVERSAL D-22U-S/M/LI-WI-22S/M/LI-WI-22U-S/M/LUNIGRIP DriversI-UGI-S/M/LI-HUG-S/M/LI-WI-UG-S/M/LNOTE: Refer to CAT-1203 for alternative drivers1 Series ScrewsScrew Head ConnectionsLaboratory ScrewUnigrip1.22 Hex1.22 HexHexUnigripTORQUE:10-15NcmHead d and forlaboratory use only) Due to design revisions screw tips may be flat or rounded.Always ensure that the correct screw is used for the relevant implant and component. Refer to CAT-1003 for alternative slotted 1 Series screwsSTECO TITANMAGNETICSMagnetic attachments for facial prosthesisDual magnet systemThe universal and easily manageable solutionfor implant-supported face prostheses andobturators.Two open magnet fields exert a forceof attraction over a longer distancethan mono-magnet systems.The construction principleProsthesesmagnetCorrosion-prooftitanium housingInsertAttachmentSm2Co17 Magnet}Implant-specificgeometry12

STECO TITANMAGNETICSTelescopic magnetsSpherical magnetsThe StecoTitanmagnetics T-Line was developedexclusively for extraoral use. The telescopic bearing of 2.5mm gives the facial prosthesis secure fixation on the tissue.The design allows a certain amount of rotation and axialmovement, without losing the withdrawal force.The slightly curved surface of the spherical StecoTitanmagnetics X-Line and the ZLine facilitates self centering and has the lowest lateral force introduction into theimplant. X-Line and Z-Line are therefore particularly suitable for short implants. Dueto the absence of lateral steering, they are also indicated for highly divergentimplants.X-LineT-LineHeight5.7 mmHeight2.65 mmProsthesis magnetØ4.80Ø5.80DistanceheightInsert AttachmentDistanceheightInsert Attachment1.4 N (143 g)Height3.15 mmProstheses magnetØ5.80DistanceheightZ-Line1.6 N (163 g)Withdrawal forceWithdrawal force3.0 N (300 g)Prosthetic ComponentsIn X-Line and Z-Line there are prostheses magnets for acrylic and, with additional retention, forsilicone. For more lateral support there are prostheses magnets with extended collars available.For siliconewith retention ringFor acrylicwith collar andretention ringwith rotation protectionIn the T-Line there are also prosthesesmagnets for acrylic and with additional retentionfor silicone.For siliconeFor acrylicwith retention ringUniversalwith collarAccessoriesTo make a new prostheses, each product line has its own compatible impression copings and laboratory analogues.Laboratory Analogues- for making models quickly and hygienically- the original implant does not have to be used on the insertionpoint of an analogue- there is no need for time-consuming cleaning- a length of 16 mm is also available on requestImpression Copings- magnetic impression without screws- lock magnetically to the insert- the external geometry ensures the impression material issecurely fixedX-LineZ-LineHealing FlangeZ-LineT-LineInsertion standard toolsThe Healing-Flange is placed on the insert to stabilizethe bandage on fresh skin perforation tissue, afterapplication of the insert. This minimizes excessive tissueproliferation. The Healing-Flange has its own magnet coreand is made off tissue friendly Titanium.X-LineX-LineT-LineX-LineZ-Line & T-LineH.00.04.X2H.00.04.T2Connector to handpieceConnector to handpieceH.00.04.X4H.00.04.T4Connector to . ratchetConnector to . ratchetH.00.04.X1H.00.04.T1Connector to I-Ratchet-2Connector to I-Ratchet-2T-Line13

IMPLANT DIMENSIONS AND INFORMATIONRANGEIMPLANT LENGTHSMAJOR PLATFORM Prosthetic HEXHEX COLLAR THREAD APEX CylindricalDIAMETER DIAMETER Colour WIDTH HEIGHT HEIGHT PITCH DIAMETER or TaperedCode(flange)C/T346 4.072.700.70.250.52.45T IETiØ4.5mm4.54.072.700.70.250.52.45T PLATFORMDIAMETER JORDIAMETERAPEXDIAMETER14

EXPLANATION OF SYMBOLSThe following symbols are used on our packaging labels and they indicate the following:Manufacturer12Implant image3Implant details and sizeDoc # 0000-0 Rev 0REF IET44STERILE R2STERILIZEExt. Hex, Tapered Implant, Ultra3 Short, Ø4.5 x 4mmSterilization using IrradiationDo not Resterilize2yyyy-mmionlyConsult instruction for useDo not reuse!CautionREF IET4Ø4.5 x 4mm672797224STERILIZELOT*REF IET4Ø4.5 x 4mmLOT*CE mark and notified body numberExpiry date1Sterile unless package is opened or damaged52D Bar codingContains the GTIN, Expiry Date and LOT Number6Patient sticker for documentation purposesSouthern Implants (Pty) Ltd1 Albert Rd, IRENE, 0062, South Africa.Southern Implants UK Ltd, Building 3, Chiswick Park566 Chiswick High Road, London W4 5YA, United KingdomAMERICAS / ASIA: Southern Implants North America, Inc,225 Chimney Corner Lane, Suite 3011, Jupiter, FL 33458,United States of AmericaECREPREF IET465(01) 00000000000000(17) Date packed(10) Expiry Date(to be used by health care provider on patient file)7Prescription deviceCAUTION: FEDERAL LAW RESTRICTS THE DEVICE TO SALE BYOR ON THE ORDER OF A LICENCED HEALTH CARE PROVIDER.15

For more information, please contact yourSouthern Implants Representative or visit southernimplants.comSouth Africa – Headquarters 1 Albert Road, Irene, RSAT: 27-12-667-1046 E: hern Implants AustraliaT: 61-2-8076-9337E: info@southernimplants.com.auUnited KingdomSouthern Implants UKT: 44-20-8899-6845 / 6 / 7E: info@southernimplants.co.ukUSA and CanadaSouthern Implants North America Inc.T: 1-561-472-0990E: customercare@southernimplants.comSouthern Implants Products are distributed world-wide, please visit southernimplants.com for a list of Distributors. 2019 Southern Implants (Pty) Ltd. All rights reserved. Co-Axis, Southern Implants,and Subcrestal Angle Correctionare registered trademarksand Body-Shift, INVERTA and PROVATA are trademarks of Southern Implants (Pty) Ltd. Not all implants are available in all markets.CAT-2010-08 (C1073)

AP-IBS D-T AP-IBS D-T AP-IBS Medium Bone Ø4.0mm Tapered (IET4 / IET4)i Soft Bone D-RB-MS Ø2.0mm Dense Bone D-RB-MS Ø2.0mm Ø4.0mm D-RB-MS Ø2.0mm Ø4.0mm NOTE: The total implant length is reached when the flange of the 4mm tapered drill touches the bone surface. Drilling beyond this point may compromise primary stability of the implant. 4mm .