Huawei SmartAX MA5616MDU and Boards Datasheet

CONTENTOverview .2Usage Scenario .2Models & Appearance .2Highlights .3Device Parameters .4Board Description .4Control Boards .5VDSL2 Service Board .7ADSL2 Service Board .14Ethernet Service Board .15Voice Service Board .15Combo Board .17Basic Ordering Information.24Where to Buy .27Source .27Contact UsTel: 1-626-239-8066 (USA) 852-3050-1066 / 852-3174-6166Fax: 852-3050-1066 (Hong Kong)Email: sales@router-switch.com (Sales Inquiries)Router-Switch.com1

OverviewHuawei SmartAX MA5616 Multi-service Access Module (MA5616 for short) is a leading remote Multi-Dwelling Unit (MDU)product, which provides various types of ports on the passive optical network (PON) and 10G PON and meets multipleservice requirement. It applies in fiber to the building (FTTB) and fiber to the curb (FTTC) scenarios. It can also functionas a mini-digital subscriber line access multiplexer (DSLAM) or multiservice access node (MSAN).Usage ScenarioThe MA5616 provides two GPON or GE upstream ports and provides multiple service by supporting flexible boardconfigurations. The MA5616 provides broadband, voice, and video services through ADSL2 /VDSL2/FE boards, voiceservices through POTS boards, leased line services through SHDSL or P2P boards.Models & AppearanceFigure 1. MA5616:Router-Switch.com2

HighlightsHigh-density AccessSupports the following users:- A maximum of 256-channel POTS users- A maximum of 256-channel ADSL2 users- A maximum of 256-channel VDSL2 users- A maximum of 64 FE usersHigh-speed Access- Vectoring cancels crosstalk between multi-pair VDSL lines.- Vectoring increases VDSL2 line rates.- SuperVector is supportedFlexible Service Configuration- Improves access density.- Reduces the equipment room space.- Simplifies routing.PSTN Network Reconstruction- Provides bandwidth access during PSTN network reconstruction.- Reduces CO equipment room rents for outdoor cabinet reconstruction.Wide Applicability- Supports the wide temperature range, low power consumption, and silent design.- Can be installed in corridors, cabinets, indoors, and outdoors.High Reliability- Supports powerful surge protection, lowering the rate of failures caused by lightening.Router-Switch.com3

- Supports the anticorrosion design, prolonging the device lifecycle.Eco-friendly and Energy-saving- Provides high-performance power supply, lowering the system power consumption.- Supports intelligent fan speed adjustment, effectively lowering the power consumption at off-peak hours.- Provides high-performance chipset, lowering the chip power consumption.- Supports POTS short-loop design, effectively lowering the port power consumption at a short distance.High-efficiency OAM- Issues configurations remotely, supporting remote commissioning.- Supports plug and pay (PnP).- Supports remote acceptance, upgrade by patch loading, and fault locating.Device ParametersH W D88.1 mm 442 mm 245 mm (without mounting ears)Weight 4.8 kg (empty chassis); 9.1 kg (chassis in full configuration)Ambient temperature-40 C to 65 C; -25 C (start)Ambient humidity5% RH to 95% RH (non-condensing)Power parametersDC power supply: -38.4 V DC to -72 V DCAC power supply: 90V AC to 264 V ACBackup powerSupports 48 V backup power; Supports lead-acid and Fe-lithium batteries.Board DescriptionHuawei SmartAX MA5616 series provides board configuration. In the MA5616 chassis, slot 0 houses the control board,slots 1-4 service boards, and slot 5 power board.Router-Switch.com4

0. Control Board1. Service BoardFan Tray2. Service Board5. Power Board3. Service Board4. Service BoardControl BoardsThe control board converges upstream services and manages devices, and manages services for each interface module.Differences Between Control Boards:ParameterH831CCUBH831CCUCH831CCUESupported daughter boardUpstream daughter board:Upstream daughter board:Upstream daughter board:- H831GP1A- H831UP2A- H831UP2A- H831GE1A- H831UP2C- H831UP2CVoice daughter board:Voice daughter board:- H831UP2AA- H836ASDA- H836ASDA- H831UP2CA- H836ASDCl H836ASDC- H833XP1A- H836ASDMl H836ASDM- H831GE4AVoice daughter board:- H836ASDA- H836ASDC- H836ASDM- H836ASDFUpstream transmission- GPON- GPON- GPONmode- EPON- EPON- EPON- GE- GE- GE- XG-PONPort on the front panel (on- CONSOLE- CON/ESC- CON/ESCthe mother board)- ESC- ETH- ETHRouter-Switch.com5

ParameterH831CCUBH831CCUCH831CCUE- ETH- CLK/TOD- CLK/TOD- ALARM- ALARM- ALARM- GE0- GE- GEUplink port (on theWhen an H831GP1AWhen an H831UP2A orWhen an H831UP2A ordaughter board)daughter board isUP2C daughter board isUP2C daughter board isconfigured:configured:configured:- GE0 (SFP port)- 0 (SFP port)- 0 (SFP port)- PON (SFF port)- 1 (SFP port)- 1 (SFP port)When an H831GE1AWhen an H833XP1Adaughter board isdaughter board isconfigured:configured: XG PON (SFP- GE0 (SFP port)port)- GE1 (SFP port)When an H831GE4Adaughter board isconfigured:- GE0 (CSFP port or SFPport)/ XGE0 (SFP port)- GE1 (CSFP port or SFPport)/XGE1 (SFP port)- GE2 (CSFP port)- GE3 (CSFP port)Cascading portRouter-Switch.comOne GE cascading portOne GE cascading portOne GE cascading port(optical or electrical)(optical or electrical)(optical or electrical)NOTENOTENOTE"optical and electrical""optical or electrical""optical or electrical"means that users can usemeans that:means that:either port GE0 on the- Both ports 0 and 1- Both ports 0 and 1daughter board or the GE0provided by a daughterprovided by a daughterelectrical port on the panelboard support both the GEboard support both the GEfor upstream transmission.optical and electricaloptical and electricalmodules to provide opticalmodules to provide optical6

ParameterSynchronous clockH831CCUBNot supportedH831CCUCH831CCUEand electrical ports. Usersand electrical ports. Userscan select either of thecan select either of theports to function as the GEports to function as the GEoptical port or electricaloptical port or electricalport.port.- Users can use either port- Users can use either port0 on the daughter board or0 on the daughter board orthe GE electrical port onthe GE electrical port onthe panel for upstreamthe panel for edtransferringVDSL2 Service BoardVDSL2 service boards provide the VDSL2 access service using broadband ports.Differences between 64-channel VDSL2 service cable line64-channel VDSL2 over POTS64-channel VDSL2 over POTS64-channel VDSL2VectoringNot supportedSupportedSupportedG.INPSupportedVDSL2 PTM bondingNot m7

MELTNot supportedSpectrum parameterSupports VDSL2 8a, 8b, 8c, 8d, 12a, 12b, and 17a profiles.profileAnnex type- G.992.1 Annex A or B- G.992.3 Annex A, L, or M- G.992.5 Annex A or M- G.993.2 Annex A/BConfiguration modeSupports TR129 and TR165Supports TR129, TI, andSupports TR129, TI,TR165/TR252andTR165/TR252Embedded splitterNot supportedTemperature query andSupportedhigh-temperature alarmAutomatic powerSupportedshutdown in the eventof a high temperatureConnectorDelander 64-pinDifferences between 48-channel VDSL2 service cable line48-channel VDSL248-channel VDSL248-channel VDSL2VectoringNot supportedSupportedSupportedG.INPSupportedVDSL2 PTM lSuperVectorSupported8

INMSupportedSELTSupportedMELTSupportedSpectrum parameterSupports VDSL2 8a, 8b, 8c, 8d, 12a, 12b, and 17a profiles.profileSupports VDSL2 8a,8b, 8c, 8d, 12a, 12b,17a, and 35bprofiles.Annex type- G.992.1 Annex A- G.992.1 Annex A- G.992.1 Annex A- G.992.1 Annex A- G.992.3 Annex A, B,- G.992.3 Annex A, B,- G.992.3 Annex- G.992.3 AnnexL, or MJ, L, or MA/B/J/L/MA/B/J/L/M- G.992.5 Annex A, B,- G.992.5 Annex A, B,- G.992.5 Annex- G.992.5 Annexor MJ, or MA/B/J/MA/B/J/M- G.993.2 Annex A or- G.993.2 Annex A or- G.993.2 Annex A/B- G.993.2 Annex A/BBBConfiguration modeSupports TR129, TI, and TR165/TR252Embedded splitterNot supportedTemperature querySupportedand hightemperature alarmAutomatic powerSupportedshutdown in theevent of a hightemperatureConnectorRouter-Switch.comChamp 64-pin9

Differences between 32-channel VDSL2 service CLEH83BVCLFH836VCLEApplicable nnel32-channelVDSL2VDSL2VDSL2VDSL2 overVDSL2VDSL2 overover POTSover rtedSupportedSupportedVDSL2 rtedSELTSupportedMELTNot supportedSpectrumSupports VDSL2 8a, 8b, 8c, 8d, 12a, 12b, and 17a profiles.parameter profileAnnex type- G.992.1- G.992.1- G.992.1- G.992.1- G.992.1- G.992.1Annex AAnnex AAnnex AAnnex AAnnex AAnnex A- G.992.3- G.992.3- G.992.3- G.992.3- G.992.3- G.992.3Annex A, L,Annex A, L,Annex A, L,Annex A, L, orAnnex A, B, J,Annex A, L, oror Mor Mor MML, or MM- G.992.5- G.992.5- G.992.5- G.992.5- G.992.5- G.992.5Annex A orAnnex A orAnnex A orAnnex A or MAnnex A, B, J,Annex A or MMMM- G.993.2or M- G.993.2- G.993.2- G.993.2- G.993.2Annex A or B- G.993.2Annex AAnnex A or BAnnex A orAnnex A or BAnnex A/BBRouter-Switch.com10

ConfigurationSupports TR129, TI, and TR165/TR252.SupportsmodeTR129 andTR165/ tter)splitter)TemperatureNot supportedSupportedSupportedquery and hightemperaturealarmAutomatic powerSupportedshutdown in theevent of a hightemperatureConnectorChamp 64-pinDifferences between 24-channel VDSL2 service cable line24-channel VDSL2 over24-channel VDSL2 over24-channel VDSL2 over POTSPOTSISDNVectoringNot supportedG.INPSupportedVDSL2 PTMSupportedbondingINMRouter-Switch.comSupported11

SELTSupportedMELTNot supportedSpectrumSupports VDSL2 8a, 8b, 8c, 8d, 12a, 12b, and 17a profiles.parameterprofileAnnex typeConfiguration- G.992.1 Annex A- G.992.1 Annex B- G.992.1 Annex A- G.992.3 Annex A, L, or M- G.992.3 Annex B- G.992.3 Annex A, L, or M- G.992.5 Annex A or M- G.992.5 Annex B- G.992.5 Annex A or M- G.993.2 Annex A or B- G.993.2 Annex A or B- G.993.2 Annex A or BSupports TR129, TI, and TR165/TR252modeEmbeddedNot supportedsplitterTemperatureNot supportedSupported (600-ohm impedancesplitter)Supportedquery and n in theevent of a hightemperatureConnectorRouter-Switch.comChamp 64-pin12

Differences between 16-channel VDSL2 service boards:SpecificationsH835VDGEApplicable line16-channel VDSL2 over POTSVectoringNot supportedG.INPSupportedVDSL2 PTM bondingSupportedINMSupportedSELTSupportedMELTNot supportedSpectrum parameter profileSupports VDSL2 8a, 8b, 8c, 8d, 12a, 12b, 17a, and 30a profiles.Annex type- G.992.1 Annex A- G.992.3 Annex A, L, or M- G.992.5 Annex A or M- G.993.2 Annex A or BConfiguration modeSupports TR129, TI, and TR165/TR252 [2].Embedded splitterSupported (600-ohm impedance splitter)Temperature query andSupportedhigh-temperature alarmAutomatic power shutdownSupportedin the event of a hightemperatureConnectorRouter-Switch.comChamp 64-pin13

ADSL2 Service BoardADSL2 service boards provide ADSL2 access services using the broadband ports.Differences Between ADSL2 Service Boards:SpecificationsH83AADLE or H835ADLEH836ADLEH836ADPEApplicable line32-channel ADSL2 over POTS32-channel64-channelADSL2 overADSL2 over POTSPOTSPort- PSTN- LINEG.INPSupportedINMSupportedSELTSupportedMELTNot supportedAnnex type- G.992.1 Annex ANot supportedNot supported- G.992.3 Annex A, L, or M (EU32-EU64)- G.992.5 Annex A or M (EU32-EU64)Configuration modeSupports RFC 2662, RFC 4706, and TR165/TR252. (Users can switch a mode. To do so, login to the MA5616 as a super user and run the switch ADSL mode to command in diagnosemode. The default configuration mode is RFC 2662. Considering the development trend,TR165 is recommended because it is more flexible than others.)ConnectorChamp 64-pinEmbedded splitterSupported (600-ohm impedance splitter)Router-Switch.comChamp 64-pinDelander 64-pin14

Temperature querySupportedand high temperaturealarmAutomatic powerSupportedshutdown in the eventof a high temperatureEthernet Service BoardEthernet service boards are used for GE or FE signal access to implement the Ethernet service.Differences Between Ethernet Service Boards:SpecificationsH831EIUDH831EIUANumber of ports4 GE optical/electrical adaptive ports and 4 FE16 FE electrical portsoptical portsOptical module- GE optical port: SFP GE optical moduleNot supported- FE optical port: SFP FE optical modulePort protectionSupportedSupportedBoard shutdown forSupportedSupportedSupportedNot supportedenergy conservationSynchronous Ethernetclock outputVoice Service BoardVoice service boards support VoIP POTS, ISDN BRA, ISDN PRA and R2 services.Specifications of POTS service boards:Router-Switch.com15

nnectorChamp 64-pinChamp 64-pinNumber of ports3264CodecG.711AG.711UG.729G.723.1G.726POTS MELTSupportedSupportedMELT precisionHighHighAutomatic power shutdown in theSupportedSupportedShort loopSupportedSupportedPolarity of wires a and ba ba b-16/12 KCSupportedSupportedPowering on/off using the CLISupportedSupportedPolarity reversalSupportedSupportedPort current20 mA, 25 mA, or 30 mA20 mA, 25 mA, or 30 mAevent of a high temperatureSpecifications of ISDN and R2 service boards:SpecificationsH832DSLDH831EDTBTypes of servicesBRAPRA or R2Router-Switch.com16

ConnectorChamp 64-pinChamp 64-pinCoding mode2B1QE1 mode: HDB3 or AMIAutomatic power shutdown inSupportedSupportedthe event of a high temperatureCombo BoardThe combo board is a broadband and narrowband combo service board and provides three application modes: combomode, broadband mode, and narrowband mode. In combo mode, the combo board supports both broadband and voiceservices.Differences Between VDSL2 and POTS Combo Boards:SpecificationsH83BCVLC orH836CCMEH83DCCMEH83DCSMEH83BCVLEVDSL2 Specifications ComparisonApplicableVDSL2 andVDSL2 andVDSL2 andSuperVector andlinePOTS comboPOTS comboPOTS comboPOTS ComboNumber of32484848VectoringNot supportedNot ingRouter-Switch.com17

SpectrumparameterprofileAnnex typeConfiguration modeSupports 8a, 8b,Supports 8a, 8b,Supports 8a, 8b,Supports 8a, 8b,8c, 8d, 12a, 12b,8c, 8d, 12a, 12b,8c, 8d, 12a, 12b,8c, 8d, 12a, 12b,and 17aand 17aand 17a17a, and 35b- G.992.1- G.992.1- G.992.1- G.992.1Annex AAnnex AAnnex AAnnex A- G.992.3- G.992.3- G.992.3- G.992.3Annex A, L,or MAnnex A, L, or MAnnex A, L, or MAnnex A/L/M- G.992.5- G.992.5- G.992.5- G.992.5Annex A or MAnnex A or MAnnex A or MAnnex A/M- G.993.2- G.993.2- G.993.2- G.993.2Annex A or BAnnex A or BAnnex A or BAnnex BSupports TR129,Supports TR129 and TR165/TR252. (Users can switch aTI, and TR165/configuration mode. To do so, log in to the MA5616 as a superTR252. (Users canuser and run the switch vdsl mode to command in diagnoseswitch amode.)configurationmode. To do so,log in to theMA5616 as a superuser and run theswitch vdsl modeto command indiagnose mode.)Embedded ature query pportedSupportedSupportedhigh temperature alarmAutomatic powershutdown in the event of ahigh temperatureRouter-Switch.com18

Connector Champ 64-pinChamp 64-pinChamp 64-pin Champ 64pinPOTS Specifications ComparisonConnectorChamp 64-pinChamp 64-pinChamp 64-pinChamp 64-pinNumber of DSP .1G.726POTS MELTSupportedSupportedSupportedSupportedMELT precisionHighHighHighHighAutomatic powerSupportedSupportedSupportedSupportedShort loopSupportedSupportedSupportedSupportedPolarity of wires a and ba a a a b-b-b-b-16/12 KCNot supported NotNot supportedNot supportedNot supportedPowering on/off using pportedSupportedSupportedshutdown in the event ofa high temperatureCLIPolarity reversalRouter-Switch.com19

Power supply at a highNot supportedNot supportedNot supportedNot supported20 mA, 25 mA,20 mA, 25 mA,20 mA, 25 mA,20 mA, 25 mA,or 30 mAor 30 mAor 30 mAor 30 mAvoltage (for a longdistance)Port currentADSL2 and POTS Combo Board cable lineADSL2 and POTS comboADSL2 and POTS comboNumber of ports3232G.INPSupportedNot supportedADSL2 bondingNot supportedNot supportedINMSupportedNot supportedSELTSupportedSupportedMELTNot supportedNot supportedAnnex type- G.992.1 Annex A- G.992.1 Annex A- G.992.3 Annex A, L, or M- G.992.3 Annex A, L, or M(EU32-EU64)(EU32-EU64)- G.992.5 Annex A or M- G.992.5 Annex A or M(EU32-EU64)(EU32-EU64)Supports RFC 2662, RFC 4706, andSupports RFC 2662, RFC 4706, andTR165/TR252. (Users can switch aTR165/TR252. (Users can switch aconfiguration mode. To do so, logconfiguration mode. To do so, log in toin to the MA5616 as a super userthe MA5616 as a super user and runADSL2 SpecificationsConfiguration modeRouter-Switch.com20

and run the switch adsl mode tothe switch adsl mode to command incommand in diagnose mode.)diagnose mode.)ConnectorChamp 64-pinChamp 64-pinEmbedded splitterSupportedSupportedTemperature query and Champ 64-pinChamp 64-pinNumber of DSP channels (G.711)3232CodecG.711Atemperature alarmAutomatic power shutdown in theevent of a high temperaturePOTS SpecificationsG.711UG.729G.723.1G.726POTS MELTSupportedSupportedMELT precisionHighHighAutomatic power shutdown in theSupportedSupportedShort loopSupportedSupportedPolarity of wires a and ba a b-b-event of a high temperatureRouter-Switch.com21

16/12 KCNot supportedSupportedPowering on/off using the CLISupportedSupportedPolarity reversalSupportedSupportedPower supply at a high voltage (for aNot supportedNot supported20 mA, 25 mA, or 30 mA20 mA, 25 mA, or 30 mAlong distance)Port currentPower BoardConnected to the external AC or DC power supply, the power board converts the voltage of such power supply into aproper voltage using its power module and powers other boards in the chassis.Differences between DC power boards:Power BoardPower Supply ModeMaximum Output PowerPower BackupDaughter board(Unit: W)H831PDIAOne -48 V DC input200Not supportedNot supportedH832PDIATwo -48 V DC inputs300Not supportedNot supportedH832PDVAOne -48 V DC input400Not supportedNot supportedH832PDVAAOne -48 V DC input400Not supportedSupported(using theH836VPBAdaughter board)H832PDNAAOne -48 V DC input400Not supportedSupported(using theH836VPDAdaughterboard)Router-Switch.com22

H832PDVSAOne -48 V DC input500NotSupportedsupported(using theH836VPSHD daughterboard)H832PDVSBOne -48 V DC input500NotSupportedsupported(using theH836VPSKD daughterboard)H832PDMSBOne -48 V DC input500NotSupportedsupported(using theH836VPMEdaughterboard)Differences between AC power boards:Power BoardPower Supply ModeMaximum OutputPower BackupDaughter boardSupported, one batterySupported(lead-acid battery or Fe-(using thelithium battery) inputH836VPBAfor power backupdaughter board)Power (Unit: W)H831PAVDAOne 220 V AC or 110400V inputH831PAIAOne 220 V AC or 110 V input200Not supportedNot supportedH831PAICOne 220 V AC or 110 V input400Not supportedNot supportedH831PAIBOne 220 V AC or 110 V input200Supported, one batteryNot supported(lead-acid battery or Felithium battery) inputfor power backupRouter-Switch.com23

Basic Ordering InformationSKUDescriptionMA5616Huawei SmartAX MA5616 Multi-service Access Module, MDU, 2 GPON or GE upstream portsH83AADLEHuawei SmartAX MA5616 32-channel ADSL2 over POTS service boardH83BCVLCHuawei SmartAX MA5616 32-channel VDSL2 and POTS combo service i SmartAX MA5616 32-channel VDSL2 and POTS combo service board, providing VDSL2and POTS integrated access servicesHuawei SmartAX MA5616 32-channel VDSL2 over POTS vectoring service board, supporting600-ohm built-in splittersHuawei SmartAX MA5616 48-channel VDSL2 service board without a built-in splitterHuawei SmartAX MA5616 32-channel VDSL2 over POTS service board, supporting 600-ohmbuilt-in splitterHuawei SmartAX MA5616 48-port VDSL2 & POTS combo board with the highest density in theindustry, providing 48 channels of VDSL2 and POTS access services and supporting vectoringHuawei SmartAX MA5616 48-port SuperVector & POTS combo board with the highest densityH83DCSMEin the industry, providing 48 channels of SuperVector and POTS access services and Switch.comHuawei SmartAX MA5616 48-channel super vector service board. It provides SuperVectoraccess service, supporting metallic line testing (MELT)Huawei SmartAX MA5616 48-channel VDSL2 service board, providing VDSL2 access service,supporting system-level vectoring functionHuawei SmartAX MA5616 64-channel VDSL2 over POTS service board, supporting vectoring24

H83DVCPEH831CCUEH831EDTBH831PAIBH832DSLDHuawei SmartAX MA5616 64-channel VDSL2 over POTS service board, supporting 600-ohmbuilt-in splitters and vectoringHuawei SmartAX MA5616 super control unit board used for copper line accessHuawei SmartAX MA5616 8-channel TDM SHDSL access services and 8-channel E1 and V.35access servicesHuawei SmartAX MA5616 AC power board (with power backup)Huawei SmartAX MA5616 8-channel ISDN service board, providing the basic rate access (BRA)user access serviceHuawei SmartAX MA5616 DC power board, supplies -48 V DC power to the backplane orH832PDVAconvert -48 V DC power to 3.3 V DC and 12 V DC and then supplies the voltages to thebackplane.Huawei SmartAX MA5616 DC power board, supplies -48 V DC power to the backplane orH832PDVSAconvert -48 V DC power to 3.3 V DC and 12 V DC and then supplies the voltages to thebackplaneHuawei SmartAX MA5616 DC power board, supplies -48 V DC power to the backplane orH832PDVSBconvert -48 V DC power to 3.3 V DC and 12 V DC and then supplies the voltages to thebackplane.H832SHLHH835ADLEHuawei SmartAX MA5616 16-channel SHDSL service board, providing SHDSL access servicesHuawei SmartAX MA5616 32-channel ADSL2 over POTS service board, supporting 600-ohmbuilt-in splittersH835VDGEHuawei SmartAX MA5616 16-channel VDSL2 over POTS service boardH835VDTHHuawei SmartAX MA5616 24-channel VDSL2 over ISDN service boardH836ADLERouter-Switch.comHuawei SmartAX MA5616 32-channel ADSL2 over POTS service board, supporting 600-ohmbuilt-in splitters25

39ASPBRouter-Switch.comHuawei SmartAX MA5616 a 64-channel ADSL2 over POTS service boardHuawei SmartAX MA5616 32-channel ADSL2 and POTS combo service board that providesADSL2 and POTS integrated access servicesHuawei SmartAX MA5616 48-port VDSL2 & POTS combo board with the high-density in theindustry, providing 48 channels of VDSL2 and POTS access servicesHuawei SmartAX MA5616 32-channel VDSL2 over POTS service board, supporting 600-ohmbuilt-in splittersHuawei SmartAX MA5616 64-channel VDSL2 over POTS service board, supporting 600-ohmbuilt-in splittersHuawei SmartAX MA5616 64-channel VoIP subscriber board, providing 64-channels VoIP POTSservicesHuawei SmartAX MA5616 64-channel VoIP subscriber board, providing 64-channels VoIP POTSservices26

Where to BuyWant to buy this series of products? please contact: Tel: 1-626-239-8066 (USA)/ 852-3050-1066 / 852-3174-6166 Fax: 852-3050-1066 (Hong Kong) Email: sales@router-switch.com (Sales Inquiries)Or visit:Huawei SmartAX MA561x SeriesHuawei SmartAX MA5616 Series BoardsAbout usRouter-switch.com, founded in 2002, is one of the biggest Global Network Hardware Supplier. We are a leading providerof network products with 14,500 customers in over 200 countries. We provide original new and used networkequipments (Cisco, Huawei, HPE, Dell, Juniper, EMC, etc.), including Routers, Switches, Servers, Storage, Telepresenceand Videoconferencing, IP Phones, Firewalls, Wireless APs & Controllers, EHWIC/HWIC/VWIC Cards, SFPs, Memory &Flash, Hard Disk, Cables, and all kinds of network solutions related se/en/doc/EDOC1000167760?idPath ter-Switch.com27

as a mini-digital subscriber line access multiplexer (DSLAM) or multiservice access node (MSAN). Usage Scenario The MA5616 provides two GPON or GE upstream ports and provides multiple service by supporting flexible board configurations. The MA5616 provides broadband, voice, and video services through ADSL2 /VDSL2/FE boards, voice