Hazlux Lighting Fixtures

Transcription

Hazlux Lighting Fixtures Safe, durable and now availablewith LED technology for superior energy efficiencyThomas & Betts Hazlux luminaires are known as high quality industriallighting fixtures designed, tested and certified for use in hazardouslocations and adverse environment conditions. Specifiers rely onHazlux to safely provide light where it’s needed — even under theharshest indoor and outdoor conditions.Safe, dependable, durable Hazlux luminaires are now available withLED technology to offer longer life, enhanced energy efficiency, reducedmaintenance, and a smaller footprint.All Hazlux LED products are designed and assembled in Canada forexceptional service and support with reduced lead times. Experiencedassembly operation easily accommodates both large and smallproduction runs with a fast turnaround.

Hazlux durability meets LED technology Superior performance lightingfor hazardous locationsHigh-efficacy luminaire offers excellent performanceand energy savingsThomas & Betts has taken the rugged,reliable design of Hazlux lighting fixturesHazluxModelAC Power(W)LumensLm/Wand introduced the capabilities of LEDDL005455 800129technology to create a high-performanceDL007587 100122luminaire with an impressive lumen output.DL0108810 000114DL01512215 600128DL01713117 800135DL02016620 400123Higher T-ratings and optimal thermal managementextend LED and driver life expectancyWith an exclusive design that maximizesheat dissipation, Hazlux LED fixtureslower internal temperature allow for higherHazluxModelTamb 40 CClasse I Div 2Tamb 55 CClasse I Div 2 etClasse IIClasse I Div 2Classe I Div 2 etClasse IIT-rating and extended LED and driver lifeDL005T5T4AT5T4in extreme ambient temperatures.DL007T5T4AT5T4With the entire luminaire acting as a heatsink, Hazlux LED fixtures allow higherwattages for better performance.IES FLOOD REPORTDL010 FILENAMET4AT4APHOTOMETRIC: G972C DL010-I6.IESDL015T4AXIALCANDELA 3Cs.os.o5816Versatile optics include reflector options3878for diffuse light distributionThe Hazlux LED fixture is available with a thermal-resistant globe and a varietyof reflectors for the ideal beam angle from 35 to 65 .1939V4H

Labor-saving installationand maintenance-friendly constructionDesigned for easy retrofit installationUsing the same mounting style options as existing Hazlux lighting fixtures,the new LED luminaires can easily be attached as retrofit fixtures.*The HazVertor adapter ring makes it easy to replace Crouse-Hinds Champ series lighting fixtures without removing the top hat from the conduit system.Hinged design for hands-free wiringEasy tank access allows Hazlux lighting fixtures to be maintainedquickly and safely. The hinged lid is designed to support,the weight of the tank, leaving both the installer s hands free.Field-replaceable LED engine and driverThe LED driver is designed in its own compartmentso it can be easily replaced in the field using a connector,with no re-wiring required. A fiberglass insulator protectsthe driver from the heat of the LED engine.Robust construction for long life expectancyCast, copper-free aluminum construction offers corrosion resistance in a strong,lightweight fixture for maximum life expectancy. Baked epoxy powder finishes and stainless steelexposed hardware provide additional corrosion resistance.Certifications shown on external surfaceAn easily identifiable nameplate displays third party certification for all electrical and hazardous location ratingsas required by the Canadian Electrical Code, OSHA regulations and CSA to provide peace of mind,confirming that the correct lighting fixture with the required certifications is in place.5

Hazlux 3 LED DL Series Assembly guideMOUNTINGSTYLEComplete luminaire consists of : Mounting Style a Tank a Globe or Refractor a Optional Guard and /or ReflectorCeiling MountHazVertor Adapter RingWall Mount25 Angle Stanchion BALLASTTANKCone-Top PendantGLOBE orREFRACTOR Heat-ResistantPrismaticGlass GlobeRefractorGlobeGUARDS PolymericGuardCastGuardREFLECTORSor EXIT SIGNS 30 Angle Reflector6StandardDomeStraight Stanchion

Class IDivision 2, Groups A, B, C and DZone 2, Groups IIC, IIB, IIAClass IIDivisions I and 2, Groups E, F and GCataloguenumbering systemClass III- UL1598A for Marine Locations- NEMA-4X- UL844- CSA C22.2 No 137Contact your Thomas & Betts sales representative to verify classificationSimultaneous Class I Division 2 and Class IILED Driver TankOptics & mounting12345DL010EUNFixture series1DL Hazlux 3 LED seriesFixture206707TGC C2101112ETI6Order assembly optionsTG R1 R3 R5 Thermal shock-resistantglass globeType I glass refractor globeType III glass refractor globeType V glass refractor globe Standard fixtureLumen output3050710151720 5,800 lumens, 45W7,100 lumens, 58W10,100 lumens, 88W15,600 lumens, 122W17,800 lumens, 131W20,400 lumens, 166WBlank C L 9A2 A3 B2 4Driver circuitB3 C2 E Electronic LED driverC3 HV1 5Voltage/FrequencyHV2 UN Universal 120 to 277VAC50/60Hz (voltage range includes L4 208V, 220V, 240V etc.)L5 UN2 Universal 347/480VACS4 50/60Hz (Not available for DL017S5 and DL020)Blank LED driver housing style0 Standard housingS Standard housingwith stainless-steel insert1110E No guardCast aluminum guardPolymeric guardMounting styleSpecial optionsT G 12Guard option8689OptionsHazCote customanti-corrosion coating(Consult factory)Grey colour optionLight distribution optionsI3 I4 I6 Internal reflector35 beam angle*Internal reflector45 beam angle*Internal reflector65 beam angle** : DL005, DL007 and DL010 only3/4 in. cone-top pendant1 in. cone-top pendant3/4 in. wall mount1 in. wall mount3/4 in. ceiling mount1 in. ceiling mountHazVertor adapter ringClass I Div. 2, Zone 2HazVertor adapter ringClass I Div. 2, Zone 2Class 21-1/4 in. straight stanchion1-1/2 in. straight stanchion1-1/4 in. 25 angle stanchion1-1/2 in. 25 angle stanchionNo mounting(to replace existing fixture)UNIPAK optionUNIPAK with LED light source7

Hazlux 3 LED DL Series IndividualComponentsCeilingMountHazVertor Adapter RingMOUNTINGOPTIONSCone-TopPendantGLOBESor olymericGuardStandardDome825 aticGlass GlobeCatalogueNumberDescriptionConduit Hub SizeVA2VA3Cone-Top Pendant3/4 in.1 in.VC2VC3Ceiling Mount3/4 in.1 in.VB2VB3-VIBWall Mount3/4 in.1 in.VS4-VIBVS5-VIB25 Angle Stanchion1-1/4 in.1-1/2 in.VL4-VIBVL5-VIBStraight Stanchion1-1/4 in.1-1/2 in.HV1HazVertor Adapter Ring Class I Div. 2, Zone 2N/AHV2HazVertor Adapter Ring Class I Div. 2, Zone 2 Class 2N/ACatalogueNumberDescriptionVGT15Heat-Resistant Prismatic Glass GlobeVGL15R1IES Type I Refractor GlobeVGL15R3IES Type III Refractor GlobeVGL15R5IES Type V Refractor GlobeCatalogueNumberDescriptionVGU22PPolymeric GuardVGU22Cast ard Dome,Fiberglass Reinforced PolyesterVRA15PAngular Dome,Fiberglass Reinforced Polyester30 AngleReflector

18-11/32 in. (466mm)Cone-TopPendantDimensions& globe photometric data16-3/4 in. (425mm)13-3/8 in. (340mm)Photometry Reference Data —Standard Housing with Globe and Guard — Ceiling MountIES ROAD REPORTPHOTOMETRIC FILENAME : G927 DL005-TG.IESCeilingMountPOLAR GRAPH1996Catalogue No.DL005EUN0TGC2ELuminaire LumensLuminaire Efficacy Rating (LER)Input WattSpacing Criterion (0-180)Spacing Criterion (90-270)Spacing Criterion (Diagonal)13-3/8 in. (340mm)Candlepower Curve5,89513145.071.31.31.441497998249916-3/4 in. (425mm)1WallMountIES ROAD REPORTPHOTOMETRIC FILENAME : G944 DL010-TG.IESPOLAR GRAPH3522Catalogue No.14-7/8 in. (378mm)15-3/16 in. (386mm)DL010EUN0TGC2ELuminaire LumensLuminaire Efficacy Rating (LER)Input WattSpacing Criterion (0-180)Spacing Criterion (90-270)Spacing Criterion (Diagonal)Candlepower Curve10,12311588.191.241.241.4264217612881125 AngleStanchionMountIES ROAD REPORTPHOTOMETRIC FILENAME : G938 DL015-TG.IESPOLAR GRAPH5363Catalogue No.15-3/16 in. (386mm)DL015EUN0TGC2ELuminaire LumensLuminaire Efficacy Rating (LER)Input WattSpacing Criterion (0-180)Spacing Criterion (90-270)Spacing Criterion (Diagonal)16-1/8 in. (410mm)Candlepower htStanchion1IES ROAD REPORTPHOTOMETRIC FILENAME : H110C DL020-TG.IESPOLAR GRAPH5876Catalogue No.14-3/4 in. (375mm)15-3/4 in. (400mm)DL020EUN0TGC2ELuminaire LumensLuminaire Efficacy Rating (LER)Input WattSpacing Criterion (0-180)Spacing Criterion (90-270)Spacing Criterion (Diagonal)20,476123166.11.461.461.58Candlepower Curve4407293821469HazVertor Ring113-3/8 in. (340mm)9

Hazlux 3 LED DL Series Refractor photometric dataPhotometry reference data —Standard ballast housing with glass refractor — Ceiling mountIES ROAD REPORTPHOTOMETRIC FILENAME : H173C DL010-R1.IESPOLAR GRAPH2890Catalogue No.DL010EUN0R1C2ELuminaire lumensLuminaire efficacy rating (LER)Total luminaire wattsMaximum CandelaMaximum Candela ( 90 Vertical)Maximum Candela at 90 VerticalMaximum Candela from 80 to 90 VerticalCandlepower Curve216814458,04792872,8902,890887 (11.0% luminaire lumens)1,463 (18.2% luminaire lumens)72321IES ROAD REPORTPHOTOMETRIC FILENAME : H196C DL010-R3.IESPOLAR GRAPH3731Catalogue No.DL010EUNOR3C2ELuminaire lumensLuminaire efficacy rating (LER)Total luminaire wattsMaximum CandelaMaximum Candela ( 90 Vertical)Maximum Candela at 90 VerticalMaximum Candela from 80 to 90 VerticalCandlepower Curve8,6499987.273,7313,731883 (10.2% luminaire lumens)1,308 (15.1% luminaire lumens)2798186693321IES ROAD REPORTPHOTOMETRIC FILENAME : H242C DL020-R5.IESPOLAR GRAPH3413Catalogue No.DL020EUN0R5C2ECandlepower Curve25601707Luminaire lumensLuminaire efficacy rating (LER)Total luminaire wattsMaximum CandelaMaximum Candela ( 90 Vertical)Maximum Candela at 90 VerticalMaximum Candela from 80 to 90 Vertical17,004102166.33,4133,4131,171.3 (6.9% luminaire lumens)1,662.7 (9.8% luminaire lumens)2853110

OverviewHazardous locationsHazardous LocationsA hazardous location is defined as an area where the possibilityof explosion and fire is created by the presence of flammablegases, vapors, dust, fibers or flyings.Class I — GasClass I locations are those in which flammable gases, flammableliquid-produced vapors or combustible liquid-produced vaporsare or may be present in the air in quantities sufficient to produceexplosive or ignitable mixtures.Typical Class I Locations: Petroleum refineries and gasoline storage and dispensing areas Industrial firms that use flammable liquids in dip tanksfor parts cleaning or other operations Petrochemical companies that manufacture chemicals from gas and oil Dry cleaning plants where vapors from cleaning fluids can be present Companies that have spraying areas where they coat productswith paint or plastics Aircraft hangars and fuel serving areas Utility gas plants and operations involving storage and handlingof liquified petroleum gas or natural gasClass II — DustDivision 1 — Normally HazardousClass II locations are those that are hazardous because of thepresence of combustible dust.Hazardous gases or dusts are present under normaloperation conditions or during frequent repair andmaintenance activity.Typical Class II Locations: Grain elevators, flour and feed mills Plants that manufacture, use or store magnesium or aluminum powders Plants that have chemical or metallurgical processes:producers of plastics, medicines and fireworks, etc. Producers of starch or candies Spice-grinding plants, sugar plants and cocoa plants Coal preparation plants and other carbon handling or processing areasClass III — FibersClass III locations are those that are hazardous because of thepresence of easily ignitable fibers or where materials producingcombustible flyings are handled, manufactured or used, but inwhich such fibers/flyings are not likely to be in suspension in the air inquantities sufficient to produce ignitable mixtures.Typical Class III Locations: Textile mills, cotton gins, cotton seed millsand flax processing plants Any plant that shapes, pulverizes or cuts woodand creates sawdust or flyingsNote: Fibers and flyings are not likely to be suspended in the airbut can collect around machinery or on lighting fixturesand where heat, a spark or hot metal can ignite them.Division 2 — Not Normally HazardousHazardous gases or dusts are not present undernormal operating conditions.Groups A, B, C, DThe gases and vapors of Class I locations are brokeninto four groups by the code A, B, C and D. These materialsare grouped according to the ignition temperatureof the substance, its explosion pressure and otherflammable characteristics.Groups E, F, GClass II dust locations groups E, F and G are classifiedaccording to the ignition temperature and the conductivityof the hazardous substance.Note: These are simplified definitions — complete datais in the Canadian Electicral Code (C.E.C)11

series lighting fixtures without removing the top hat from the conduit system. Hinged design for hands-free wiring Easy tank access allows Hazlux lighting fixtures to be maintained quickly and safely. The hinged lid is designed to support the weight of the tank, leaving both the installer, s hands free. Field-replaceable LED engine and driverFile Size: 762KBPage Count: 9