Calculite LED 6 Gen 3 C6RDL Round Downlight - Signify

Transcription

DownlightingCalculite LED 6" gen 3C6RDL Round DownlightProject:Calculite LED 4" generation 3 provides excellent performance coupled with optimizedinstallation flexibility via UniFrame. Industry leading visual comfort and uniform illuminationmake it an ideal choice for open office, institution, healthcare, and retail applications.Location:Cat.No:Type:Standard luminaire: Complete luminaire Frame Engine Trim Accessories (optional)Qty:Buy American Act of 1933 (BAA)** Compliant luminaire*: Complete luminaire Frame-BAC Engine-BAC Trim-BACNotes:* BAA compliance requires that BAC option be selected for each of frame, engine, and trim. Frame and engine will be ordered/shipped together;trim will be ordered/shipped separately. Accessories (optional) are not currently BAA-compliant.FrameSeriesstandard example: 6RN BAC example: 6RN-BACInstallationVoltage / OptionsN New construction— Universal 120/277/347V 13 347 V (for non-0-10v configurations) 2EM6 Emergency, 6W Self-Test/Self-Diagnostic 3LCChicago Plenum 4RADIO Integral Interact Pro RF sensor (requires above ceilingBAC eets the requirements of theMBuy American Act of 1933 (BAA) **— Universal 120/277/347V 13 347 V (for non-0-10v configurations) 2BAC eets the requirements of theMBuy American Act of 1933 (BAA) **6R6R 6" Non-ICRoundRRemodelerEngineSeriesaccess and enables wireless connected lighting control)standard example: C6L15835NZ10U BAC example: ions10 1000 lm15 1500 lm20 2000 lm25 2500 lm 530 3000 lm 535 3500 lm48 4800 lm8 80 CRI9 90 CRI27303540N Narrow (40 )M Medium (56 )W Wide (76 )Z10 0-10 V 1%U 120/277V3 347V 6.7 (0-10v only)RRetrofitBACMeets therequirementsof the BuyAmericanAct of 1933(BAA) **C6LC6L CalculiteLED 6"gen 32700 K3000 K3500 K4000 K(Z10 only)60 6000 lm(Z10 only)SOL EldoLED Solo 0-10 V 0.1%U 120/277/347VDDali 0.1%LLutron LDE1 EcoSystem (fade-to-black)DMX Digital MultiplexingE ELV (for up to 2000lm only)1PE Ethernet 48 V DCPower over Ethernet (PoE)120 VOnly compatible with 1000 (10) to 2500 (25) lumen configurations.TrimSeriesC6C6 CalculiteLED 6"gen 3standard example: C6RDLCCPApertureStyleFinishDL DownlightBK BlackBAC example: C6RDLCCP-BACFlangeOptionsRRRound8CCCDCZComfort clearComfort clear diffuseChampagne bronze–PFWH White (matte)–FWHAMF White (gloss antimicrobial)–White (matte)IEM6Polished (matches aperture)Trim mountedFlangeless (requires CA6RFT) EM test switchBACWhite (matches finish)Flangeless (requires CA6RFT) Meets the requisitesof the Buy AmericanWhite (matches finish)Act of 1933 (BAA) **WH White (matte)WHAMF White (gloss antimicrobial)–(not applicable)(annodized)CLSL Shower lightAccessories Specular clear** Failure to properly select the “BAC” suffix(Not currently BAA-compliant) learn more on page 2SBA Interact Ready System Bridge Accessory (refer to Philips System Bridge Accessory spec sheet for options and details)AMSActiLume multi-sensor (optional accessory for PoE configurations)7925Sloped ceiling 6" adapter for 6RN and 6RA framesCA6RFT Mud-in ring for use in 6" round flangeless trim installations (ordered with a flangeless trim)CAEM6 Field-installable Bodine BSL6 6W battery pack with self-test/self-diagnostic (for new construction frames, 120-277V)C6RVPWH IP65 Rated vandal proof matte white accessory mounts onto flangeless trims (C6RDL*F) and new construction frame only1. Specify standard Universal frame for use with 347V light engines.2. Not compatible with electronic low voltage light engine dimming option (E).3. Emergency (EM6) frame is compatible with reflector mounted test switch when light engine isordered with IEM6 option code (not compatible with 347V or Power over Ethernet configurations).4. Chicago Plenum (LC) frame is not available for Buy American Compliant (BAC) configurations.5. The 2500lm (25) and 3000lm (30) packages have marked spacing requirements (see page 6).6. The 347V light engine voltage option available only with Z10 dimming option.For other dimming protocols order UNV (U) light engine and 347V (3) frame.CalculiteLEDgen3 6in Downlight C6RDL 02/22 page 1 of 9could result in you receiving product thatis not BAA compliant product with norecourse for an RMA or refund. This BACdesignation hereunder does not address(i) the applicability of, or availability of awaiver under, the Trade Agreements Act,or (ii) the “Buy America” domestic contentrequirements imposed on states, localities,and other non-federal entities as acondition of receiving funds administeredby the Department of Transportation orother federal agencies.7. Universal 120-347V for 0-10v (Z10) dimming only. For 347Vnon-Z10 dimming, order 347V (3) frame with (U) light engine.8. Non-conductive flush mount lens with pre-installed gasket(matte white non-conductive flange with diffuse lens that is flush with the flange).WETLOCATION

C6RDL Calculite LED 6" gen 3Round DownlightFrame-in-kitsEmergencyOptions and AccessoriesNew Construction:Galvanized stamped steel for dry or plasterceilings. Preinstalled telescoping mounting barsfrom 13" to 24". For 4' distances, use 1/2" EMT,1-1/2" x 1/2" U or C channel.Bodine BSL6 6W battery pack with self-test/diagnostic functionality. Factory or field mountedto frame.Flangeless mud-in ring: Use CA6RFTfor use with flangless plaster installations.Max ceiling thickness is 2.75" (70 mm)including PoE frame 4.88" (124 mm)plenum depth for installation.Patented install Mounting frame: Pre-installed mounting bars for fast and toolless installs into T-grid & hat channel ceilings. For trim with integral emergency test switch,order trim with IEM6 option (ex: C6RDLCCIEM6). For remote ceiling mounted test switch,order standard trim (ex: C6RDLCC). Optionalaccessory ceiling mounting plate available(CAEM6TSCP) for remote mounted test switch. Refer to Calculite-LyteProfile-EasyLyteEmergency Battery Pack specification sheetfor more details. Close-cut aperture design eliminatespossibility of gap between ceiling openingand reflector flange.Dimming Separate wiring compartment for wiring frameto building allows inspection prior to lightengine install.- Lutron Hi-lume EcoSystem H Series 1% dimming- Advance 0-10V 1% dimming- EldoLED ECOdrive Dali 1% dimming Simple plug-and-play connection betweenframe and light engine from below ceiling.- EldoLED SOLOdrive 0-10V 0.1% dimmingRetrofitPower over Ethernet Easily updates legacy Calculite downlights tothe latest LED technology. Includes light engine,trim, and driver mounted on cover plate thatmounts to junction box of previous Calculitegenerations. Order with RH option code at endof light engine catalog number (see details onpage 5).Powered via Lightolier PoE lighting controller:Complies with FCC rules per Title 47 part 15(Class A) for EMI / RFI (conducted & radiated). PoElighting controller accessible from below ceiling.Compatibility:Comfort throughout the space:True 50 physical cutoff and 45 reflected cutoff.- EldoLED DMX POWERdriveOptical systemsSloped ceilings: Compatible with sloped ceilingadapters (see SCA spec sheet).C6RVPWH: includes machined aluminum ringpainted white, gasketed for IP65 protection,and impact resistant polycarbonate lens (IK10).Locks in place with discrete setscrew (keyincluded). Available also with antimicrobial fiinsh(C6RVPWHAMF).CAEM6TSCP: Ceiling cover plate for remotemounted EM6 test switch. 1/2" (25mm) hole,4 3/8" (109mm) x 2 3/4" (69mm) rectangular.Includes two mounting screws.Field Installed Emergency: Refer to CalculiteLyteProfile-EasyLyte Emergency Battery Packspecification sheet for more details.CAEM6: Field install EM6 kit with Bodine BSL66W battery pack with self-test/self-diagnostic,mounts to new construction frames. Includesremote ceiling plate for test switch. To mount testswitch to trim for new construction frame, ordertrim with IEM6 option code (e.g. C6RDLCCIEM6).SBA: Interact Ready System Bridge Accessory.Requires IRT9015 IR remote and Interact Pro Appfor commissioning.ENERGY STAR exceptions- 90 CRI configurations- Champagne Bronze & Black finishes- 347V & Emergency voltage/optionsFramesEnginesWith CFLS6132 seriesUse Retrofit configurationC6R Trim C6L EngineQuality of light:2 SDCM ensures color consistency from fixtureto fixture and over the luminaire’s long lifetime.With INCBS600 seriesUse Retrofit configurationC6R Trim C6L EngineLight Engine- 1 000lm configurationsWith LEDC6L N seriesC6X6L N seriesP6RD N seriesUse Retrofit configurationC4R Trim C6L EngineC6S Trim C6L EngineC6R Trim C6L EngineQuick connect power pack allow for easyinstallation and replacement from below ceilingwith no need for additional wiring. This allows for:- Champagne Bronze & Black finishes Frame and ceiling installation to be performedwhile still finalizing details such as lumenpackages, CCT and control type.- cULus listed for wet locations* Not available for retrofitting luminaireswith integral emergency battery. Easy replacement of electronics at end of lifewith minimal wasted material and labor required.- Dali, EldoLED Solo & PoE driversTitle 24 exceptionsLabels and Listings- ENERGY STAR certified- RoHS certified- CEC Title 24 JA8 certified Ease and upgradability of technology.- CCEA (frames with *LC suffix) 347V light engines are 0-10v dimming onlyand include dedicated 347V driver for usewith universal 120/277/347V (U) frames. For347V and non-0-10v dimming, order (U) lightengine and 347V (3) frame (includes stepdown transformer).- IP65 rated with vandal proof accessoryCalculiteLEDgen3 6in Downlight C6RDL 02/22 page 2 of 9Warranty5 year limited warranty Visit Signify.com/warrantiesfor more information on Signify'sstandard 5- year limited warrantyon complete luminaire systems.

C6RDL Calculite LED 6" gen 3Round DownlightInteract Pro scalable systemFoundationAdvancedEnterpriseDimming, grouping, and zoningBluetooth and ZigBee enabledMotion sensing and daylight harvestingIntegration with 0-10V and phase dimming fixturesCode complianceGranular dimming and dwell timeEnergy reporting and monitoringSchedulingDemand responseBMS integration (BACnet)Floor plan visualizationIoT sensors for wellnessIoT Apps for productivityInteract Proscalable system architectureCurrently supported maximum system sizeTo be able to design the lighting system correctly for thecustomer, it is important to know the prime characteristicsof the system, its possibilities and limitations.System levelBACNetTotal number of gatewaysUnlimitedTotal number of devices200 per network luminaires withintegrated sensors150 smart TLEDS150Total number of ZGP devices(sensors and switches)50 sensors30 switches50 zones and groups64InteractIOT platformBuildingconnectivity bridge(BCB)BMSsystemITinfrastructureInteract Pro EnterpriseWirelessgatewayWirelessgatewayInteract Pro AdvancedGroup levelRecommended number of lights40 (recommended 25)Number of ZGP devices5Number of scenes16InteractPro chExternalbatteryWireless luminairespowered with integrated sensorsensor0-10V control Phase dimmingmodulemodulePlug loadcontrol moduleInteract Pro FoundationCalculiteLEDgen3 6in Downlight C6RDL 02/22 page 3 of 9

C6RDL Calculite LED 6" gen 3Round DownlightWireless Controls OptionsInteract Pro scalable sensor(System Bridge Accessory with -CS option):Interact Pro Enterprise(System Bridge Accessory with -SB option):Emergency Options (ER100)(System Bridge Accessory with -ER100 option): CS is a connected sensor with integraloccupancy and daylight sensing and supportswireless mesh connectivity. A wireless IoT connected lighting solution forlarge enterprises that span across multiplefloors, buildings and require multiple gateways. The sensor works in the Foundation mode(similar to SpaceWise) when configured withouta gateway or in an Interact Pro Advanced orEnterprise mode if a compatible gateway is used. View all your projects under one dashboard andeasily compare insights from multiple projectsin one view. Power Sensing (Factory default) –Recommended UL924 option requiresunswitched power sense line, absence ofvoltage on the normal circuit triggers luminaireto 100% output Interact Pro includes an App, a portal and abroad portfolio of wireless luminaires, lamps andretrofit kits all working on the same system. Startup is implemented via Interact Pro App(Android or iPhone) & BlueTooth connectivity.The App provides flexibility to choose between agateway or non gateway mode for setup. Setup with the gateway requires wired internetaccess to the gateway. It is possible to add agateway at a later point. Prepare project configuration steps remotelyand use IRT9015 remote onsite to identify andgroup devices together. Compatible with:- UID8451/10 wireless dimmer switch- SWS200 wireless scene switch- Battery powered IP42 presence sensor OCCsensor IA CM WH 10/1- Battery powered IP42 presence & daylightsensor OCC-DL sensor IA CM IP42 WH- Battery powered IP65 presence sensor OCCsensor IA CM IP65 WH- Battery powered IP65 presence & daylightsensor OCC-DL sensor IA CM IP65 WH For more information on Interact Pro esystem. Compatible with UID8451/10 wireless dimmerswitch, SWS200 wireless scene switch, wirelessOcc sensor (OCC SENSOR IA CM IP42 WH 10/1)and wireless Day/Occ sensor (OCC MULTISENSOR IA CM WH 10/1) and wireless Occupancyor Daylight & Occupancy sensors available. Use Interact software and insights to increasebuilding efficiency, achieve building wideintegration and optimize space throughoccupancy analytics. SB option in addition to occupancy and daylightsensing supports advanced IoT capabilitiessuch as people estimation analysis, desklevel temperature & humidity sensing, noiseclassification, and BLE beacon. Power Interruption Detection (Field option) –Detects AC power interruption 30ms triggers90 minute emergency mode with luminaire at100% outputRadio only sensor (RADIO): Integral RADIO only sensor simply enableswireless mesh connectivity to the luminairewithout any occupancy or daylight sensing. Ideal for applications where sensingfunctionality is managed by other Interactdevices and the luminaire only needs to havewireless connectivity. Requires compatible Gateway and internetconnectivity for commissioning. For more information, visit:www.interact-lighting.com/office /offices.Wired Controls OptionsInteract Office Wired (PoE): PoE based IoT connected lighting solution forlarge enterprises that span across multiplefloors, buildings and require multiple gateways. Optional integral emergency controller andbattery pack provides 600lm nominal output. Test switch and indicator light mounted on sideof chassis on one end. Use Interact Office software and insights toincrease building efficiency, achieve buildingwide integration and optimize space throughoccupancy analytics. Emergency battery has a 3 month pre-installedshelf life, and must be stored and installedin environments of 20C to 30C (-4F to 86F)ambient, and 45-85% relative humidity. Supports advanced IoT Apps on PersonalControl, Space Management, wayfinding, room/desk reservation and offers open APIs for lightcontrol and data exchange. For more information on Interact Office Wired,visit: www.interact-lighting.com/office /offices. PoE lighting controller is accessible from below.Interact Office Wired (PoE), Static White: Integral sensor option for occupancy sensing(PIR) and/or daylight harvesting available foradditional energy savings. A wireless IoT connected lighting solution forlarge enterprises that span across multiplefloors, buildings and require multiple gateways.CalculiteLEDgen3 6in Downlight C6RDL 02/22 page 4 of 9 View all your projects under one dashboard andeasily compare insights from multiple projectsin one view. Compatible Zigbee Green Power wall dimmer andwireless Occupancy or Daylight & Occupancysensors available. Use Interact Office software and insights toincrease building efficiency, achieve buildingwide integration and optimize space throughoccupancy analytics. Supports advanced IoT Apps on wayfinding,room/desk reservation and offers open APIs Requires compatible Interact Office Gatewayand internet connectivity for commissioning. For more information on Interact OfficeWireless, visit: www.interact-lighting.com/office or offices.

C6RDL Calculite LED 6" gen 3Round DownlightNew Construction (N)Chicago Plenum (LC)Emergency batterypack shown withEM6 option onnew constructionnon-IC frame.12 3 812in3 8 in314 mm314 mm8 1 2 in12 3 8 in8 1 2 in314 mm209209mm mm8 1 2 in209 mm13 1 4 13in 1 4 in337 mm337 mm1 0 1 81in0 1 8 in257 mm257 mm10 3 810in3 8 in264 264mm mm1 0 1 8 in257 mm10 3 8 in264 mm6n inmm161 mmnmmCenter point locationfor integral emergencytest switch (IEM6)3 ⅜"(85 mm)Remodeler (R)ø6 inø6 in152 mm152 mmø7 3 8ø7in3 8 inø6in184 mm184 mm152 mmø7 3 8 in184 mm10 in254 mm1 0 1 8 in257 mm1451 82 14in 1 2 in19498368368mm mmEmergency batterypack shown withEM6 option onnew constructionnon-IC frame.6 3 8 in6 3 8 in161 mm161 mm7 1 4 in7 1 4 in184 mm184 mm2 3 4 in2 3 4 inCeilingCeilingCutoutCutout70 mm70 mm8 in3 8 inø6 3 ø6MaximumMaximumin2 3 4ceiling162 mm162 mmceilingCeiling Cutout70thicknessmmthicknessø6 3 8 inMaximum162 mmceilingthickness7 1 4 in184 mm10 1 8 in257 mm10 3 261 0 1 8 in257 mm13 5 8 in346 mm47 8 in125 mm63 8 in163 mm6 in161 mm38D81 2 in216 mm6 3 8 in161 mm5 in127 mm10 3 8 in264 mm13 5 8 in346 mm13 1 4 13in 1 4 in337 mm337 mm19 5 8 inVandal498mmRetrofit (R) with round trim13 in337 mm14CA4SFT6 in165 mm12Detail Dø6 in152 mmø7 3 8 inin5 8 in 184 mm19 5 819498498mm mmDetail D7 1 4 in7 1 4 in184 184mm mm7 1 4 in184 mmCeiling Cutoutø6 3 8 in162 mm270MaxcethicProof (VP) accessoryCA6SFT6 in161 mm6 in161 mmMaxium CeilingThickness38ø6 in152 mmø7 1 4 in184 mmCACA6RFTFlangeless mud-in ring (CA6RFT) accessory17 in3 8 in3 8 in448 mm10 mm10 mmin7 8 inø5 7 8ø5149 mm149 mm12 1 4 in3 8 inD312 mm (max.)10 mmø7 37 84ø7in3 4 inø57 in196149 mm196 mm178 mmø7 3 4 in196 mmø4 1 2 in114 mm4 inø5 3 4 in4 mm 146 mm6 3 8 in161 mm8 1 2 in209 mmCA4RFT6 3 8 in161 mm6 3 8 in6 3 8 in161 mm161 mm12 3 8 in314 mm14 1 2 in368 mm58hm0mm4 in7 mmm13 5 8 in346 mm6 3 8 in161 mm1 0 1 81in0 1 8 in257 mm257 mmin5 8 in19 5 819498498mm mm13 5 813in5 8 in346 346mm mm3813 1 4 in10 in10337in mm254 254mm mmDCeiling Cutoutø6 5 8 inmm7 8 in6167176 mm385 inø6 in152 mm127 mmø7 3 8 in187 mmDetail DCalculiteLEDgen3 6in Downlight C6RDL 02/22 page 5 of 9Lensed Wall Wash(LW): 2 1 2 in 64mmWall Wash ø6 inmm(WW, DW, CW): 2 3 4 in 15270mmø7 3 8 in187 mmø5 in149 mm78D8 in215 mm12ø7 3 4 in65196 8 inmm167 mmDetail D6 7 8 in3 8 in175mm10 mmø7 3 8 in187 mø8 5 8 in219 m

C6RDL Calculite LED 6" gen 3Round DownlightNarrowMedium/WideInputvoltsLight engine120VC6L10 NZ10U/3277V120VC6L15 NZ10U/3277V120VC6L20 NZ10U/3277V120VC6L25 NZ10U/3277V120VC6L35 NZ10U/3277V120VC6L48 NZ10U/3277V120VC6L60 /60Hz50/60Hz50/60HzInput Drive Input LEDTHD Powercurrent current power power power 0.190.480.21230 mA9W8W340 mA15W11W460 mA590 mA900 mA1250 mA22W25W36W51W1400 mA 57WNarrow (Power over Ethernet)16W21W30W44W50W 15% 0.95 20% 0.95 10% 0.95 15% 0.95 10% 0.95 15% 0.95 10% 0.95 15% 0.95 10% 0.95 15% 0.95 10% 0.95 15% 0.95 10% 0.95 15% 0.95120VC6L10 MZ10U/3277V120VC6L15 MZ10U/3277VC6L20 MZ10U/3120V277V120VC6L25 MZ10U/3277V120VC6L35 MZ10U/3277VC6L48 MZ10U/3C6L60 MZ10U/3120V277V120V277VInputfreq50/60HzInput Drive Input LEDTHD Powercurrent current power power power 950/60Hz9W8W320 mA15W11W550 mA0.0950/60Hz210 mA430 mA0.0750/60HzMedium (Power over Ethernet)InputLight engineInputvoltsLight engine0.25570 mA0.110.36810 mA0.160.501130 mA0.2219W23W30W40W57WLight engine19W25W34W50W 0.95 0.95 10% 0.95 15% 0.95 10% 0.95 15% 0.95 10% 0.95 15% 0.95 10% 0.95 15% 0.95 10% 0.95 15% 0.95 10% 0.95 15% 0.95Wide (Power over Ethernet)InputVolts1 Voltage2 Freq Current Power15W 15% 20%InputVolts1 Voltage2 Freq Current PowerLight engineVolts1 Voltage2 Freq Current PowerC6L10 NPE53V51-54VDC160 mA8.9 WC6L10 MPE53V51-54VDC160 mA8.4 WC6L10 WPE53V51-54VDC160 mAC6L15 NPE53V51-54VDC250 mA 13.7 WC6L15 MPE53V51-54VDC230 mA 12.5 WC6L15 WPE53V51-54VDC230 mA 12.5 WC6L20 NPE53V51-54VDC330 mA 17.7 WC6L20 MPE 53V51-54VDC310 mA 16.7 WC6L20 WPE 53V51-54VDC310 mA 16.7 WC6L25 NPE53V51-54VDC420 mA 22.8 WC6L25 MPE 53V51-54VDC390 mA 21.4 WC6L25 WPE 53V51-54VDC390 mA 21.4 W1. Nominal input volts.2. Preferred volt range.Marked spacing applicationsLight engineLifetime (TM-21) data4800 lm6000 lmLumensNarrow beamMedium/Wide beam*C6L Z10 seriesXXC6L L series——C6L D 90 @ 60,000hrs.L90 @ 60,000hrs.6000lmL90 @ 60,000hrs.L80 @ 60,000hrs.Modules marked with an X require marked spacing:- Center-to-center of adjacent luminaires: 24" (610mm)- Luminaire center to side building member: 12" (305mm)* Lutron 3500lm with Medium/Wide beam is L85 @ 60,000hrs.In accordance with CAN ICES-005-A/ NEB-005-A and FCC Part 15-A.CalculiteLEDgen3 6in Downlight C6RDL 02/22 page 6 of 98.4 W

C6RDL Calculite LED 6" gen 3Round DownlightPolished ReflectorsFlangesSpecular clear (CL): Most specular and mostefficient finish, delivers maximum photometricperformance but can produce a mirror imageeffect of the interior space.Champagne bronze (CZ): Semi-specular finishthat softens light at the source of the reflectorwhile providing a warmer reflector appearance(slightly warmer).White (–): (matte) Provides the smoothesttransition to ceilings when off.Comfort clear (CC): Semi-specular finish thatsoftens the light at the source of the reflectorand creates a subtle, even luminance fromthe reflector cone.White (WH): (matte) Brightest illuminatedaperture and provides the smoothest transitionto most ceilings when off (white is only availablewith a white flange).Polished (P): (matches aperture) Producesa continuous look throughout the reflector(aperture matching).Comfort clear diffuse (CD): Slightly diffuseclear finish, that eliminates iridescence andreduces the mirror image effect inherentwith specular finishes.Black (BK): (anodized) Specular finish thatprovides the lowest aperture brightness possibleand significantly reduces source identification ina ceiling.Flangeless (F): (flush-mount)Creates a flush,virtually seamless transition from aperture to ceiling.Vandal proof (VP): Provides an elegant solutionfor vandal resistant needs. One piece machinedaluminum ring with impact resistant clear lens.Flangeless (F) flange must be ordered. Providesthe luminaire with an IK10 impact and IP65 rating.Shower light (SL): Wet location rated showerlight applicable in any installation requiring deadfront trims, interior or exterior non-corrosiveapplications, or where a diffused lens at theceiling is required (non-conductive).Mud-in ring (FT): Low profile, machined aluminummud-in ring provides a raised rib to plaster up toand a 3 16" flange thickness. The ring is attachedto the ceiling material as opposed to the frame-inkit to avoid conduction of heat and vibration whichcan cause yellowing or cracking of the plaster.CalculiteLEDgen3 6in Downlight C6RDL 02/22 page 7 of 9

C6RDL Calculite LED 6" gen 3Round DownlightNarrow beam, 2500lm Engine, 103.0 lm/W or 108.0 lm/W at 22.8W (Power over Ethernet)Zonal summaryZoneLumens12500-300-400-600-902500AngleMean 30272456193697735220587134321101037505000Frame: C6RN or 6RNEngine: C6L25835NZ10UTrim: C6RDLCLOutput lumens:Input watts:CRI:CCT 1:Spacing Crit.:Beam Angle:2462 lms23.9 W80 min3500K0.640 Single unit ishCCTLumensCLCCCDCZWHBK80CRI 4000K 103%80CRI 3500K 100%80CRI 3000K 95%80CRI 2700K 93%90CRI 3000K 83%90CRI 2700K 78%6000lm4800lm3500lm2500lm2000lm1500lm1000lm 100% 95% 87% 63% 87% 57%Spacingon centerInitial center beamfoot-candlesWattsper sq. 0.3338' x 38' x 10' Room, Workplane 2.5'above floor, 80/50/20% ReflectancesEfficacy: 103.0 lm/wReport2: F37145 202%192%140%100%80%60%40%Coefficients of utilization80%CeilingMultiple unit data - RCR 227011981371017761* Beam diameter is where foot-candlesdrop to 50% of maximum.8342Adjustment factorsHeight toInitial center beamBeamlighted planefoot-candlesdiameter (ft)*Wall70RCRRoom Cavity RatioCandela Curve503070%10501050%501030%500%100Zonal cavity method - Effective floor reflectance 20%012345678910119 119 119 119 116 116 111 111 106 106 100114 112 109 107 110 106 105 102 102 99 95109 105 101 98 103 97 100 95 97 93 90105 99 95 91 98 90 95 89 93 88 85100 94 89 85 93 85 90 84 88 83 8096 89 84 80 88 79 86 79 84 78 7692 84 79 75 83 75 82 74 81 74 7288 80 75 71 79 71 78 71 77 70 6985 76 71 67 76 67 75 67 74 67 6581 73 68 64 72 64 72 64 71 64 6278 70 65 61 69 61 68 61 68 61 59Medium beam, 2500lm Engine, 115.2 lm/W or 114.7 lm/W at 21.4W (Power over Ethernet)Zonal summaryZoneLumens7500-300-400-600-901500AngleMean 2809247218801178644347153236432111022503000Frame: C6RN or 6RNEngine: C6L25835MZ10UTrim: C6RDLCLOutput lumens:Input watts:CRI:CCT 1:Spacing Crit.:Beam Angle:2454 lms21.3 W80 min3500K0.855 1896231924502454Single unit '7'8'9'124804.0'4.8'5.6'6.4'7.2'Spacingon centerInitial center beamfoot-candlesWattsper sq. 0.3038' x 38' x 10' Room, Workplane 2.5'above floor, 80/50/20% ReflectancesEfficacy: 115.2 lm/wReport2: F37135FinishCCTLumensCLCCCDCZWHBK80CRI 4000K 102%80CRI 3500K 100%80CRI 3000K 97%80CRI 2700K 87%90CRI 3000K 77%90CRI 2700K 73%6000lm4800lm3500lm2500lm2000lm1500lm1000lm 100% 95% 87% 63% 87% 57% 240%192%140%100%80%60%40%Coefficients of utilization80%CeilingMultiple unit data - RCR 2423111580594536* Beam diameter is where foot-candlesdrop to 50% of maximum.8423Adjustment factorsHeight toInitial center beamBeamlighted planefoot-candlesdiameter (ft)*WallRCRRoom Cavity RatioCandela 9 119 119 119 116 116 111 111 106 106 100114 111 109 107 109 105 105 102 101 99 94108 104 100 97 102 96 99 94 96 92 88103 97 92 89 96 88 93 87 91 85 8298 91 86 82 90 81 88 80 86 79 7794 86 80 76 85 76 83 75 81 74 7289 81 75 71 80 71 78 70 77 70 6885 76 70 66 76 66 74 66 73 66 6481 72 66 62 71 62 70 62 69 62 6077 68 63 59 68 59 67 58 66 58 5774 65 59 55 64 55 63 55 63 55 541. Correlated Color Temperature within specs as defined in ANSI NEMA ANSLG C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products.2. Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products.CalculiteLEDgen3 6in Downlight C6RDL 02/22 page 8 of 90Zonal cavity method - Effective floor reflectance 20%

C6RDL Calculite LED 6" gen 3Round DownlightCandela CurveZonal summaryZoneLumens3750-300-400-600-90750AngleMean 17601740162914081083700270399532111011251500Frame: C6RN or 6RNEngine: C6L25835WZ10UTrim: C6RDLCLOutput lumens:Input watts:CRI:CCT 1:Spacing Crit.:Beam Angle:2307 lms21.3 W80 min3500K1.172 1394205923022307107.8 lm/W at 21.4W (Power over Ethernet)Single unit 6655'6'7'8'9'15.5'6.6'7.7'8.8'9.9'Spacingon center5'6'7'8'9'Initial center beamfoot-candles104.168.348.840.732.5Wattsper sq. ft.0.940.620.440.370.3038' x 38' x 10' Room, Workplane 2.5'above floor, 80/50/20% ReflectancesEfficacy: 108.3 lm/wReport 2: F37140FinishCCTLumensCLCCCDCZWHBK80CRI 4000K 102%80CRI 3500K 100%80CRI 3000K 97%80CRI 2700K 87%90CRI 3000K 77%90CRI 2700K 73%6000lm4800lm3500lm2500lm2000lm1500lm1000lm 100% 95% 87% 63% 87% 57% 240%192%140%100%80%60%40%Coefficients of utilization80%CeilingMultiple unit data - RCR 21216445332520* Beam diameter is where foot-candlesdrop to 50% of maximum.2323Adjustment factorsHeight toInitial center beamBeamlighted planefoot-candlesdiameter (ft)*WallRCRRoom Cavity RatioWide beam, 2500lm Engine, 108.3 lm/W l cavity method - Effective floor reflectance 20%119 119 119 119 116 116 111 111 106 106 100113 110 108 105 108 104 104 100 100 97 93107 102 98 94 100 93 97 91 94 89 85101 94 89 85 93 84 90 83 88 81 7995 87 81 77 86 76 84 76 82 75 7290 81 75 70 80 70 78 69 77 69 6685 75 69 64 75 64 73 64 72 63 6180 70 64 59 70 59 68 59 67 58 5776 66 59 55 65 55 64 54 63 54 5272 61 55 51 61 51 60 50 59 50 4968 57 51 47 57 47 56 47 55 47 451. Correlated Color Temperature within specs as defined in ANSI NEMA ANSLG C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products.2. Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. 2021 Signify Holding. All rights reserved. The information provided hereinis subject to change, without notice. Signify does not give any representationor warranty as to the accuracy or completeness of the information includedherein and shall not be liable for any action in reliance thereon. The informationpresented in this document is not intended as any commercial offer and doesnot form part of any quotation or contract, unless otherwise agreed by Signify.CalculiteLEDgen3 6in Downlight C6RDL 02/22 page 9 of 9Signify North America Corporation400 Crossing Blvd, Suite 600Bridgewater, NJ 08807Telephone: 855-486-2216Signify Canada Ltd.281 Hillmount Road,Markham, ON, Canada L6C 2S3Telephone: 800-668-9008All trademarks are owned by Signify Holding

(enbales wireless connected lighting control)1,2 EM 3Emergency (see page 2 for details and limitations) LC Chicago Plenum4 3 347 V (not compatible with ELV dimming) 3RADIO Integral Interact Pro RF sensor (enbales wireless connected lighting control)1,2 BAC Meet