Sales SupportProduct InformationProduct Color FinishesTresco’s lighting products are available in eight standard color finishes:White, Black, Chrome, Gold, Nickel, Antique Brass, Aluminum and Oil Rubbed Bronze. Pleaserefer to the individual Product Sections for color availability of each product.White (WH)Black (BL)Chrome (CH)Gold (GD)Nickel (NI)(Brushed)Antique Brass (AB)Aluminum (AL)(mill)Oil RubbedBronze (ORB)ETL and UL – Testing, Inspection and Certification Both are independent non-profit labs — not government agencies or government fundedETL is the largest worldwideUL is the largest in the USABoth are Nationally Recognized Testing Laboratories (NRTL) as recognized by OSHABoth are recognized by local inspectors throughout North AmericaNo mark is better than the otherTresco Products Tested and Certified forCanada and the United StatesETL or UL marks serve as proof of productcompliance to Canadian and U.S. standards.When products bear these marks, it indicatesto the consumer that the products have passeda complete and thorough set of tests andcertification requirements.All TRESCO lighting systems are registeredand certified by ETL and/or UL. In addition, amajority of our individual lighting components(lights, power supplies, and accessories) arealso registered and certified by ETL and/or UL.UL’s Recognized Component MarkThe UL Recognized Component Mark is used oncomponents that are a part of larger products or systems.It is certified by UL to both Canadian and U.S. requirements.CE MarkCE Marking permits a product to besold throughout the European Union. Itis a conformity mark noting the productcomplies with all applicable EuropeanDirectives.* The ETL Mark is a registered trademark of Intertek.The UL Mark and Recognized Component Mark are registered trademarks of Underwriters Laboratories Inc.All product dimensions and specifications are subject to change without prior notice.1-800-227-1171 trescolighting.com

Sales SupportColor 00K5000K5000KDaylightDaylight arm WhiteWarmWarmWhitetoWarmNeutralWarmWhiteto NeutralWarm to NeutralWarm toCoolNeutralWarmWhite toCoolNeutralWhiteCool White Cool WhiteCool WhiteHas BluishTint (SkyHasColor)Bluish Tint (SkyHasBluishColor) Tint (SkyHRecommendedr Earth ndedEarth forTonesEarthRecommendedforTonesEarth Tones forRecommendedEarthTransitionalTones forRecommendedBetweenEarthTransitionalTonesWarm and Whites/Blue/CoolTonesWarmHighlightsand CoolWhites/Blue/CoolTonesHighlights ilyUsed Primarilyfor PrimarilyBacklighting/SignsUsed lightlyThan Incandescent“Whiter” EquallyIncandescentHighlightWill Equally HighlightWill PrimarilyEqually HighlightCommercialWill CommercialPrimarilyUse CommercialUse CommercialUse Used for PrimariEarth Tones and CoolEarthTonesTones andEarthCoolTonesTonesand CoolEarthTonesTones and CoolEarthTonesTones and Cool Tonesod GrainsHighlightsWood GrainsHighlightsWood GrainsNot RecommendedNotforRecommendedResidentialNot Recommendedfor ResidentialNotforRHighlightsWood GrainsHighlightsWoodHighlightsGrains Wood GrainsHighlights Wood GrainsHighlights Wood GrainsRecommended forRecommendedWhiteRecommendedfor WhiteforRecommendedWhiteforRecommendedWhitefor WhiteRecommended forRecommendedRecommendedforforRecommended forRecommended foresidentialPrimarily dentialPrimarilyResidentialPrimarily commendedNotforRecommendedWoodNot edWoodfor rain/Earth TonesGrain/Earth TonesGrain/Earth TonesGrain/Earth TonesGrain/Earth eNot RecommendedNotforRecommendedWhitefor WhiteNot Recommendedfor orWillWhiteWill Give WhiteanWillOff-WhiteGive WhiteLookanOff-WhiteGive WhiteLookanWillOff-WhiteGive WhiteLookanWillOff-WhiteGive WhiteLookan Off-White LookColor temperature is the rating a particular color renders on the Kelvin scale. These colortemperatures alter how an object or room is perceived when illuminated, and Tresco Lightingoffers a wide range to choose from.The color temperatures available for each Tresco light are listed in their product specificationchart. To find the appropriate color temperature range for your application, please reference thetable above.1-800-227-1171 trescolighting.com

Sales SupportUnderstanding the Importance of Light SpreadAny puck-style, under-cabinet light should have a light spread of at least 90º in order to avoid spot lighting.The cases noted here have light spreads of 25º and 45º. In the case of the 25º light spread, each fixture needs to be spaced amaximum of 8” apart to avoid spot lighting, and the 45º light would need to be placed 12” apart. In both cases, narrow beamlights produce higher foot-candle (FC) readings but limited coverage. Simply choosing higher FC readings and ignoring thebeam angle leads to unintentional spot lighting.When compared to competitor lighting options, using a Tresco 3W provides 127 lumens with 120º spread versus only 28 and70 lumens with spreads of 25 and 45 . This allows Tresco 3W pucks to be spaced 20” apart, creating continuous lightingwithout scallops or shadows. Only five Tresco lights are needed to illuminate the countertop surface and backsplash, 45%81”less than the competition. 81”COMPETITOR LIGHTINGCOMPETITOR LIGHTING5” spaces between fixtures270”2 dead spots12” to full saturationPuck fixture25º spread8” spaces between fixtures281”2 dead spots10.5” to full saturationPuck fixtureDead spots40º spreadEven illumination occurs12” below wall cabinetsDead spotsEven illumination occurs10.5” below wall cabinetsLights required9 9Lightsrequired81”TRESCO LIGHTING18-20” spaces between fixtures114”2 dead spots3.5” to full saturationTRESCO 3WIlluminatescomplete workspaceand backsplashL-POC-3LEDSFRTRESCO fixture 120º spreadEven illumination occurs3.5” below wall cabinetsTRESCO Fixture 120º Spread25º40º120ºCompetitor lightsdo not illuminatecomplete worskpace(backsplash is dark)1-800-227-1171 trescolighting.com

Sales SupportLuniformluniform (loo-nuh-fawrm) n. The technologyto eliminate “dotted” appearances and reduceunwanted glare within light emitting diodefixtures.SECONDARY OPTICSSecondary optics are lighting components uniquely designed to diffuse LED diodes and reduce glare, suchas special lenses and proprietary films.T5 LEDEurolinxDiode BlendingFilm for InfinexDIODE TECHNOLOGYDiode technology allows for up to 10X the amount of LED diodes on a single circuit board or substrate,resulting in greater light output and a uniform beam spread.SimpLED 2.0Power Pockit 5W1-800-227-1171 trescolighting.com

Sales SupportT5 Fluorescent vs. T5 LED Case StudyRetailer X approached Tresco Lighting to outfit their stores withfluorescent, or in the alternative LED.T5 FluorescentDescription3’ T5 Fluorescent2’ T5 FluorescentWattage21W13WQty Cost/EA15 / 19.738 / 18.50T5 LEDExtended 295.95 148.00DescriptionWattage3’ T5 LED, Daylight 14W2’ T5 LED, Cool7WTOTAL MATERIAL COST: 443.95Maintenance Cost (30,000 hr period)46 Bulbs X 4.00Replacement Bulb Cost: 184.00Qty Cost/EA15 / 41.258 / 24.35Extended 618.75 194.80TOTAL MATERIAL COST: 813.55Maintenance Cost (30,000 hr period)0 Bulbs RequiredReplacement Bulb Cost: 0.00Labor to Replace Bulbs3 hours X 20/hourLabor for Replacements: 60.00Labor to Replace Bulbs0 labor requiredLabor for Replacements: 0.00Disposal Fee (bulbs) 0.60 per bulb X 46 bulbsTotal Bulb Disposal Fee: 27.60Disposal Fee (bulbs)0 bulbs to dispose ofTotal Bulb Disposal Fee: 0.00Energy Cost to Operate (30,000hr period)Description3’ T5 Fluorescent2’ T5 FluorescentWatts/EA2113Energy Cost to Operate (30,000hr period)Qty158Total Watts315104Description3’ T5 LED, Daylight2’ T5 LED, CoolWatts/EA147Qty158Total Watts21056Total Watts 419Total Watts 266419W X 30,000hrs/1000 X .10/KwhEnergy Cost to Operate: 1,257.00266W X 30,000hrs/1000 X .10/KwhEnergy Cost to Operate: 798.00TOTAL LIFETIME COST: 1,972.55TOTAL LIFETIME COST: 1,611.55Note: Most T5 Fluorescent Ballasts are 20K rated.400 stores x 361 savings would equal 144,400 (20.14%) savings forRetailer X over a 3 year period for choosing LED over fluorescent.1-800-227-1171 trescolighting.com

Sales SupportBasicSpecificationsSpecificationstotoBasic 12VLightsLightsInstallTrescoInstall Tresco 12V a PLUG-INPowerSupplyWithWitha PLug-InPowerSupplyTo control each light individually, useOption 1.To control all lights at the same time, use Option 2.Note: Before making final connections, make sure to add up all the wattageof the lights used. Do not exceed the wattage rating of the Power Supplyand each Controller.note: 12VDC plug-in Power Supplies are dimmable onthe 12VDC side only.LegenD:A.B.C.D.Select either a 12W,18W or 60W PowerSupply.(1) Mounting Block isincluded with each 12W,18W or 60W Power Supply.12VDC LED LightsFor example: an 18WPower Supply canpower up to (18) 1WLights or (6) 3W Lights.Up to (6) Controllers and/or Lights can plug into (1)Mounting Block.Select from six different types ofTresco Controllers.1. Remote Control Dimmers2. Manual Rotary Dimmer3. Motion Sensor Controls4. Photo/Light Sensor Control5. Touch Dimmer Controls6. Door SensorC.D.Power SupplyOption 1:Mounting BlockControllersTresco LightsUp to six Controllers plugged into (1) Mounting BlockA.Power SupplyB.Mounting BlockControllersTresco LightsOption 2: One Controller plugged in before the Mounting BlockA.Power SupplyC.ControllerB.Mounting BlockTypical Installation Showing One Controller for All Lights (Linear vs. Puck)120VWallOutlet12VDC Power SupplyMounting Block12VDC Power SupplyMounting Block12VControllerD.Tresco LightsSide view (Puck Light Install)120VWallOutlet12VDC Power 7-1171 trescolighting.com2409 Plantside Dr. Jeffersontown, KY 40299800-227-1171 Fax: 502-491-2215cservice@trescolighting.com

Sales SupportBasicBasicSpecificationsSpecificationstoto InstallTrescoInstallTresco 12V12VLightsLightsTo turn all lights on/off at the same time, use a Wall To control (dim) all lights at the same time, use a Wall Dimmer.WithaaHArDWIreHARDWIRE PowerWithPower SupplySupply120VSwitch.Note: Before making final connections, make sure to add up all the wattageof the lights used. Do not exceed the wattage rating of the Power Supply.120VA.Wall Switch orLeD Wall DimmerIf using Wall Switch, thePower Supply requires a50% load. If using Dimmer,the Power Supply requiresno minimum load.LED Wall Dimmer 150Wmaximum capacity.B.Dimmable HardwirePower Supply (60W Max.)C.Mounting Block(optional)D.Tresco LightsDimmable by standardLED Wall dimmers.Caution: Cannotdima Receptacle.ThisThisis aispotentialhazardandCaution:DO NOTdima receptacle.a potentialhazardcancancauseLightsto flickeras wellas damagePowerpowerSupply.andcauselightsto flickeras wellas damagesupply.Typical Hardwire Installation for 12V Pockit LightsHardwire 12VDC Mounting BlockPower Supply(optional)Hardwire 12VDCPower SupplyMounting Block(optional)red 120V WiringBlue 12VDC Wiring120V120VLegenD:12VWall Switch orWall DimmerWall Switch orWall DimmerSide view (Linear Install)Typical Hardwire Installation for 12V Linear LightsHardwire 12VDCPower SupplyHardwire 12VDCPower Supply120V12VWall Switch orWall DimmerWall Switch orWall Dimmer120V1-800-227-1171 trescolighting.com2409 Plantside Dr. Jeffersontown, KY 40299800-227-1171 Fax: 502-491-2215cservice@trescolighting.com

Sales LightswithTrescoTresco 12Vwith Framelessor FramedCabinetsfor forFramelessor FramedCabinets To wire a kitchen with Tresco 12V lights, first roughly lay outlighting system to help verify final positioning of all components.Make sure to add up all the wattage of the lighting system. Do notexceed the wattage rating of the Power Supply. If using a TrescoD.I.Y. Controller, do not exceed the wattage of the Controller.In-Wall Wiring:For in-wall wiring – typically used for frameless cabinets –use 16-gauge Class 2 wire (minimum) to route wire through kitchenwalls (see 1st illustration below).For outside of wall wiring – typically used for framed cabinets – usewires provided with Tresco lighting fixtures with appropriate link andextension leads (LINKD series) that are available in several lengths.Note: A licensed electrician should be consulted for wiring through wallsand other permanent structures. When mounting and wiring a light system,follow all local electric codes and the National Electrical Code (NEC).Typical for FRaMElESS Cabinets(example installation of 12VDC Linear Lights)WCON(BarrelConnectors)Wires that are attached to or accompany Tresco lighting systemsare not approved for in-wall use. Class 2 wire must be used(purchased separately). Class 2, 16-gauge wire is the minimum forin-wall applications.Side view120VWallOutlet12VDC PowerSupply120V WallOutlet12VRed 120VPurple Class 2 WireBlue 12VdCWCON(BarrelConnectors)(above cabinets)lEgEnd:12VDCPowerSupply12V16-gaugeClass 2 wirefed insidewall16-gaugeClass 2 wirefed insidewallWCON12V wire that accompanies LightsWCONOuTSIdE of Wall Wiring:Typical for FRaMEd CabinetsSide view(example installation of 12VDC Pockit Lights)MountingBlock12VDC PowerSupply120V WallOutlet120VWallOutlet(above cabinets)12V12VDCPowerSupplyMountingBlock12VWires thataccompanyTresco lightingfixtures are fedbehind orin-betweencabinetslength of Wire from Power Supply to Run of lightsThis is a general guide based on a 60 Watt/5 Amp load:- Recommended maximum length using Class 2, 16-gauge (AWG) wire 7.6 meters (25 ft.)- Recommended maximum length using links/extensions that accompany Tresco lights 4.6 meters (15 ft.)1-800-227-1171 trescolighting.com2409 Plantside Dr. Jeffersontown, KY 40299800-227-1171 Fax: 502-491-2215cservice@trescolighting.com

Sales ith ingJunctionBetweenIn-Wall Wiring & light Fixture WireIn-Wall Wiring & Light Fixture Wire Wires that are attached to or accompany Tresco lighting systems are notapproved for in-wall use. Class 2, 16-gauge wires must be used (purchasedseparately). Class 2, 16-gauge wire is the minimum for in-wall applications.Note: A licensed electrician should be consulted for wiring through wallsand other permanent structures. When mounting and wiring a light system,follow all local electric codes and the National Electrical Code (NEC).Items required for in-wall installation: (10) Barrel Connectors White . . . . . . . . . . . . . . . . . L-LED-WCON-WH-1Black . . . . . . . . . . . . . . . . . . L-LED-WCON-BL-1 Class 2, 16 AWG wireWhite, 15.2 m (50 ft.) roll . . . L-16CL2-WH50-1White, 76.2 m (250 ft.) roll . . L-16CL2-WH250-1 Small screwdriverBlack, mini slotted . . . . . . . L-MFSCRWDR-1note: Make sure electrical polarity (positive and negative) is correctly maintained whenmaking junction between Class 2 wire and Light Fixture wire.( ) Red to ( ) Red(-) Black to (-) BlackNote: Fixture wires are tagged ( ) (-) when red- and black-colored wires are not utilized.WCOn - Barrel ConnectorsClass 2Wire fromPowerSupplyClass 2 WireWire toLightsTypical In-Wall Wiring with Kitchen Cabinets(example installation of 12V Linear Lights)12VWCON(BarrelConnectors)12VDC PowerSupply16-gauge Class 2 wirerouted inside wall aroundwindows, etc.120V WallOutlet(above cabinets)12V16-gaugeClass 2wire fedinsidewallWCONLighting Link CordWCON1-800-227-1171 trescolighting.comWCON2409 Plantside Dr. Jeffersontown, KY 40299800-227-1171 Fax: 502-491-2215cservice@trescolighting.com

Sales ltageVoltage drop is the amount of electric current lost due to theresistance of the conductors (wires). o12VLighting LightSeriesPockit(Puck)LightSeriesPockit(Puck)On most installations – even larger installations – voltage drop isnot an issue, but excessive voltage drop could result in diminishedlight output. Keeping wire length in mind is a best practice to ensureoptimum light performance. For instance, if specifications recommend that the maximum lengthfrom Power Supply to the first Light not exceed 5 meters (16 ft.), thelight will still work if you exceed that length! Again the loss isgradual, but an excessive length could result in dimmer light. Note: The information provided for measuring voltage drop is ageneral guide only based on the length of the run and assuming 50%load (30W). Voltage drop goes down with less load and voltage dropgoes up with more load. Other factors may influence voltage drop. Allmeasurements and calculations are approximate.Other factors also influence voltage drop, including the number ofconnectors, quality of the conductor (aluminum vs. copper wires), andcross-sectional area (gauge). In-wall wiring: Wires that are attached to or accompany Trescolighting systems are not approved for in-wall use. Class 2, 16-gauge(AWG) wires must be used (purchased separately).All Tresco wires and cords provided are specifically for wiringoutside of walls and have a 4.6 meters (15 ft.) maximum lengthrecommendation. All Tresco Power Supplies can be applied to the information providedherein on voltage drop.Ideally, Voltage Drop variance should be within 5%.Absolute maximum should never exceed 8%.For in-wall wiring, stranded Class 2, 16-gauge wires must be used(purchased separately). Also if needed, lower gauge (which meanslarger wire) helps reduce voltage drop by lowering overall resistance. Recommended maximum length using links/extensions thataccompany Tresco lights 4.6 meters (15 ft.). Recommended maximum length using Class 2, 16-gauge wire 7.6 meters (25 ft.).12V Pockit Lights (Puck)Example 1:2.1 m (7 ft.)-2.3%Total length of wires0.3 m (1 ft.)12V0.15 m(6 in.)2 m (79 in.)0.15 m(6 in.)Voltage Drop11.7V#1120VMountingBlock12VDC PowerSupplyCord thatcomes withlight4 m (13 ft.)Example 2:12V0.15 m(6 in.)-4.3%Total length of wires0.3 m (1 ft.)Tresco LightVoltage Drop3.7 m (12 ft.)0.15 m(6 in.)1.8 m(72 in.)2m(79 in.)11.5V#2120VMountingBlock12VDC PowerSupply12VCord thatcomes with Tresco Lightlight(1) L-LED-LINKD-180extension cord-10.3% TOTALVoltage Drop9.5 m (31 ft.)Example 3:Total length of wires-6% Voltage-4.3% Voltage4 m (13 ft.)12V0.15 m(6 in.)1.8 m(72 in.)1.8 m(72 in.)Drop fromMounting Blockto LightDrop fromPower Supply toMounting Block0.15 m(6 in.)11.5V5.5 m (18 ft.)1.8 m(72 in.)1.8 m(72 in.)2m(79 in.)10.8V#3120V12VDC PowerSupply12V(2) L-LED-LINKD-180extension cordsMountingBlock(2) L-LED-LINKD-180extension cordsCord thatcomes withlightTresco LightNote: The overall Voltage Drop variance between Light #1 and Light #3 is 8%, which is noticeable.1-800-227-1171 trescolighting.com2409 Plantside Dr. Jeffersontown, KY 40299800-227-1171 Fax: 502-491-2215cservice@trescolighting.com

Sales SupportUnderstandingVoltageVoltage DropDropTresco’s longest linking cords are 2 meters (79 in.) which is only a2% voltage drop – without a noticeable difference in light output. Note: The information provided for measuring voltage drop is a generalguide only based on the length of the run and assuming 50% load (30W).Voltage drop goes down with less load and voltage drop goes up withmore load. Other factors may influence voltage drop. All measurementsand calculations are co 12V12VLightingLightingLinear Linkable SeriesLinear Linkable Series 12V Linear Lights Linked in Series Using Link CordsLinear Lights are typically within 1 meter (3 ft.) of each other without a noticeable voltage drop (less than 1%).Example 1:-1.3% TOTAL1.2 m (4 ft.)Voltage DropTotal length of wires-0.7% Voltage Dropfrom Power Supply to Light0.6 m (2 ft.)12V120V0.3 m (1 ft.)0.3 m (1 ft.)MountingBlock12VDCPowerSupply-0.3% Voltage Drop0.3 m (1 ft.)11.9Vfrom previous Light0.3 m (1 ft.)11.9VLight #2Light #112V-0.3% Voltage Dropfrom previous LightFirst Voltage Drop is critical to ensure that thestart of a run is within 5-8% variance maximum.11.8VLight #3Secondary Voltage Drop is often less critical,since excessive link cord use is not typical.The total Voltage Drop is 1.3% with a variance between Light #1 and Light #3 of 0.6% which is not noticeable.Example 2:-7% TOTAL6.4 m (21 ft.)Voltage DropTotal length of wires12V120Vfrom Power Supply to Light0.3 m (1 ft.)0.3 m (1 ft.)MountingBlock12VDCPowerSupply-0.3% Voltage Drop-0.7% Voltage Drop0.6 m (2 ft.)12V11.9V-6% Voltage Dropfrom previous Light0.3 m (1 ft.)from previous Light5.5 m (18 ft.)11.9VLight #2Light #111.2V(3) L-LED-LINKD-180The total Voltage Drop is 7% with a variance between Light #1 and Light #3 of 6.3% which is not noticeable.Example 3:-9% TOTAL8.2 m (27 ft.)Voltage DropTotal length of wires3.7 m (12 ft.)4.0 m (13 ft.)12V120V12VDCPowerSupplyLight #3extension cords0.15 m(6 in.)3.7 m(12 ft.)0.15 m(6 in.)(2) L-LED-LINKD-180extension cordsMountingBlock1.8 m(72 in.)12V-8.3% Voltage Dropfrom Power Supply to Light2m(79 in.)(1) L-LED-LINKD-18011.0V0.3 m (1 ft.)Light #1-0.3% Voltage Dropfrom previous Light11.0VLight #20.3 m (1 ft.)-0.3% Voltage Dropfrom previous Light10.9VLight #3extension cordVoltage Drop to Light #1 is above 5-8% variance.Run of lights will be dimmer than expected.The total Voltage Drop is 9% with a variance between Light #1 and Light #3 of 0.7% which is not noticeable.1-800-227-1171 trescolighting.com2409 Plantside Dr. Jeffersontown, KY 40299800-227-1171 Fax: ighting.com

1-800-227-1171trescolighting.com

1-800-227-1171 trescolighting.com Product Information Tresco’s lighting products are available in eight standard color finishes: White, Black, Chrome, Gol