IntraLase Technology - OftalmoTrade

Transcription

IntraLase TechnologyInnovative Technology forTruly Custom-Designed LASIK Flaps

The unparalleled uniformity and precision, biomechanical stability, and unsurpassed safety profile delivered by IntraLaseTechnology are key components of the iLASIK Technology Suite.Biomechanical Stability Stronger flaps through faster wound healing1 Increased adhesion postoperatively1Enhanced Safety Flap creation safety advantages Postoperative safety advantages Over 3.5 million procedures and countingUnparalleled Uniformity and Precision Unparalleled control over flap parameters such as:diameter depth edge angle centrationAMO offers two innovative laser platforms. Both lasersystems embody IntraLase Technology, an essentialelement of the iLASIK Solution. IntraLase FS Laser System— Gives surgeons unparalleled control for safer,precision-designed treatments iFS—Femtosecond Laser SystemHas all the features of the IntraLase FS System,plus increased speed and enhancedflap-customization capabilities. For example,surgeons can make an inverted bevel-in side cutand select an elliptical flap option Significantly smoother stromal bedsAdvanced Corneal Options IntraLase Enabled Keratoplasty (IEK) Intrastromal ring implantationFaster Visual RecoveryIntraLase Technology Showed Faster Visual Recovery2At all time points measured, the percentage of eyes that achieved a postoperative UCVA of 20/20 or betterwas significantly higher in the femtosecond group.Faster Visual Recovery100%Percentage of eyes that achieved uncorrectedvisual acuity of 20/20 or betterIntraLase Technology:Two Innovative Laser PlatformsFemtosecondMicrokeratome95%90%A retrospective analysis of 1,000 eyestreated with the IntraLase FS Laser and1,000 eyes treated with a mechanicalmicrokeratome (N 2,000).96%93%93%93%89%85%86%83%80%75%1 Day1 Week1 MonthFollow-upThe IntraLase FS and iFS Laser Systems are ophthalmicsurgical lasers indicated for use in patients undergoingsurgery or treatment requiring the initial lamellarresection of the cornea. Contraindications may includecorneal edema, glaucoma, and keratoconus. Risks andcomplications may include corneal pain, flap tearing,and epithelial ingrowth. Patients are requested to consultwith their eye care professional for a complete listing ofcontraindications and risks. U.S. Federal law restricts thisdevice to sale, distribution, and use by or on the order ofa physician or other licensed eye care practitioner.96%3 Month

The unparalleled uniformity and precision, biomechanical stability, and unsurpassed safety profile delivered by IntraLaseTechnology are key components of the iLASIK Technology Suite.Biomechanical Stability Stronger flaps through faster wound healing1 Increased adhesion postoperatively1Enhanced Safety Flap creation safety advantages Postoperative safety advantages Over 3.5 million procedures and countingUnparalleled Uniformity and Precision Unparalleled control over flap parameters such as:diameter depth edge angle centrationAMO offers two innovative laser platforms. Both lasersystems embody IntraLase Technology, an essentialelement of the iLASIK Solution. IntraLase FS Laser System— Gives surgeons unparalleled control for safer,precision-designed treatments iFS—Femtosecond Laser SystemHas all the features of the IntraLase FS System,plus increased speed and enhancedflap-customization capabilities. For example,surgeons can make an inverted bevel-in side cutand select an elliptical flap option Significantly smoother stromal bedsAdvanced Corneal Options IntraLase Enabled Keratoplasty (IEK) Intrastromal ring implantationFaster Visual RecoveryIntraLase Technology Showed Faster Visual Recovery2At all time points measured, the percentage of eyes that achieved a postoperative UCVA of 20/20 or betterwas significantly higher in the femtosecond group.Faster Visual Recovery100%Percentage of eyes that achieved uncorrectedvisual acuity of 20/20 or betterIntraLase Technology:Two Innovative Laser PlatformsFemtosecondMicrokeratome95%90%A retrospective analysis of 1,000 eyestreated with the IntraLase FS Laser and1,000 eyes treated with a mechanicalmicrokeratome (N 2,000).96%93%93%93%89%85%86%83%80%75%1 Day1 Week1 MonthFollow-upThe IntraLase FS and iFS Laser Systems are ophthalmicsurgical lasers indicated for use in patients undergoingsurgery or treatment requiring the initial lamellarresection of the cornea. Contraindications may includecorneal edema, glaucoma, and keratoconus. Risks andcomplications may include corneal pain, flap tearing,and epithelial ingrowth. Patients are requested to consultwith their eye care professional for a complete listing ofcontraindications and risks. U.S. Federal law restricts thisdevice to sale, distribution, and use by or on the order ofa physician or other licensed eye care practitioner.96%3 Month

Biomechanical StabilityEnhanced Safety with UnparalleledUniformity and Precision3-Month Comparative Measurementof Flap Tensile Strengths1Peak Force Measured6005003x strongerthan AMADEUSMicrokeratome4002x strongerthan AMADEUSMicrokeratome300Flap Creation Safety AdvantagesPostoperative Safety AdvantagesReduces or eliminates several complications including: Less ectasia3-53-5 Buttonhole or free flaps Reduced higher-order aberrations (HOAs) Irregular flaps Improved contrast sensitivity and lowerenhancement rates Microperforations Decentered flaps200 Epithelial defectsThe unique computer-controlled laser system enables surgeons to create thin, planar flaps with a uniform mean thickness of112 5 µm and an average standard deviation of as little as 4 µm within each flap,6 maximizing residual bed and potentiallyproducing a more stable post-LASIK cornea.Average SBK Flap Thickness— Prof. Dr. Michael C. KnorzFreeVis LASIK Zentrum,Universitätsklinikum Mannheim, verallAverageSD 5 µm160113“These studies were statistically significant and certainly suggestthat the inverted bevel design of the IntraLase flap is far morestable than mechanically created flaps. The ability to preciselycreate truly customized flaps for every patient further validatesthe iLASIK Procedure.”Unparalleled Uniformity and Precision Give You the Ability toPrecision-Design Your Patients’ Intracorneal Architecture113IntraLase iFS Laser140 Side Cut110IntraLase iFS Laser70 Side Cut110MicrokeratomeAMADEUS1131000“All-laser” IntraLase Technology offers numerous safety advantages over microkeratome technology both duringflap creation and postoperatively.MicronsGrams of force required to lift700In New Zealand White rabbit eyes, threegroups of flaps were created with eitherthe AMADEUS microkeratome, iFSLaser 70 side cut angle, or iFS Laser140 side cut angle. At 3 months, aforce gauge was attached to a curvedlens and pulled perpendicularly until theflap dehisced and peak force could bemeasured. Note the IntraLase FS Laserhas a side cut angle up to 90 .100806040200Courtesy of Jason Stahl, MD, Durrie Vision, Overland Park, KS, USA.-4 -1 1 4-4 -1 1 4-4 -1 1 4-4 -1 1 4MillimetersCourtesy of Jason Stahl, MD, Durrie Vision, Overland Park, KS, USA.N 25

Biomechanical StabilityEnhanced Safety with UnparalleledUniformity and Precision3-Month Comparative Measurementof Flap Tensile Strengths1Peak Force Measured6005003x strongerthan AMADEUSMicrokeratome4002x strongerthan AMADEUSMicrokeratome300Flap Creation Safety AdvantagesPostoperative Safety AdvantagesReduces or eliminates several complications including: Less ectasia3-53-5 Buttonhole or free flaps Reduced higher-order aberrations (HOAs) Irregular flaps Improved contrast sensitivity and lowerenhancement rates Microperforations Decentered flaps200 Epithelial defectsThe unique computer-controlled laser system enables surgeons to create thin, planar flaps with a uniform mean thickness of112 5 µm and an average standard deviation of as little as 4 µm within each flap,6 maximizing residual bed and potentiallyproducing a more stable post-LASIK cornea.Average SBK Flap Thickness— Prof. Dr. Michael C. KnorzFreeVis LASIK Zentrum,Universitätsklinikum Mannheim, verallAverageSD 5 µm160113“These studies were statistically significant and certainly suggestthat the inverted bevel design of the IntraLase flap is far morestable than mechanically created flaps. The ability to preciselycreate truly customized flaps for every patient further validatesthe iLASIK Procedure.”Unparalleled Uniformity and Precision Give You the Ability toPrecision-Design Your Patients’ Intracorneal Architecture113IntraLase iFS Laser140 Side Cut110IntraLase iFS Laser70 Side Cut110MicrokeratomeAMADEUS1131000“All-laser” IntraLase Technology offers numerous safety advantages over microkeratome technology both duringflap creation and postoperatively.MicronsGrams of force required to lift700In New Zealand White rabbit eyes, threegroups of flaps were created with eitherthe AMADEUS microkeratome, iFSLaser 70 side cut angle, or iFS Laser140 side cut angle. At 3 months, aforce gauge was attached to a curvedlens and pulled perpendicularly until theflap dehisced and peak force could bemeasured. Note the IntraLase FS Laserhas a side cut angle up to 90 .100806040200Courtesy of Jason Stahl, MD, Durrie Vision, Overland Park, KS, USA.-4 -1 1 4-4 -1 1 4-4 -1 1 4-4 -1 1 4MillimetersCourtesy of Jason Stahl, MD, Durrie Vision, Overland Park, KS, USA.N 25

Significantly SmootherStromal BedsNew Capabilities from the LatestFemtosecond LaserIntraLase Technology results in significantly higher-quality stromal beds than are possible with theFEMTO LDV .The iFS Femtosecond Laser System has all the features of the IntraLase FS System, plus increased speed andenhanced flap-customization capabilities that include: Stromal bed roughness with the iFS Laser was 39.55 nm Stromal bed roughness with the IntraLase FS Laser was 41.20 nm Stromal bed roughness with the Ziemer FEMTO LDV Laser was 42.87 nm Inverted bevel-in side cut up to 150 Tighter spot separation — provides smoother stromalbeds and a virtually effortless flap lift Elliptical flap option Higher repetition rate and faster procedure time —enhance patient comfort and confidence Lower energy per pulse — may reduce tissue responseand inflammation High-resolution video microscope — for maximumsurgeon comfortElliptical Flap Enhances Surgical Options D istributes forces symmetrically to the ellipticalcorneaiFS Laser (9x)iFS Laser (300x) P revents resection of the vital peripheral cornealfibers that contribute greatly to the biomechanicalstrength of the cornea M oves the hinge peripherally to maximize stromalbed exposure for full delivery of excimer ablationElliptical FlapRound Flap A llows use of a wider hinge angle to createflap stabilityIntraLase FS Laser (9x)IntraLase FS Laser (300x)Inverted Bevel-In Side CutZiemer FEMTO LDVLaser (9x)Ziemer FEMTO LDVLaser (300x)Images of the IntraLase FS Laser and Ziemer FEMTO LDV Laser are provided by Dr. Daniel S. Durrie.Inverted bevel-in side cut, customizable to 150 ,promotes flap replacement, positioning and adhesionfor optimal biomechanical stability of the post-LASIKcornea.150 Inverted Side Cut Option to 150

Significantly SmootherStromal BedsNew Capabilities from the LatestFemtosecond LaserIntraLase Technology results in significantly higher-quality stromal beds than are possible with theFEMTO LDV .The iFS Femtosecond Laser System has all the features of the IntraLase FS System, plus increased speed andenhanced flap-customization capabilities that include: Stromal bed roughness with the iFS Laser was 39.55 nm Stromal bed roughness with the IntraLase FS Laser was 41.20 nm Stromal bed roughness with the Ziemer FEMTO LDV Laser was 42.87 nm Inverted bevel-in side cut up to 150 Tighter spot separation — provides smoother stromalbeds and a virtually effortless flap lift Elliptical flap option Higher repetition rate and faster procedure time —enhance patient comfort and confidence Lower energy per pulse — may reduce tissue responseand inflammation High-resolution video microscope — for maximumsurgeon comfortElliptical Flap Enhances Surgical Options D istributes forces symmetrically to the ellipticalcorneaiFS Laser (9x)iFS Laser (300x) P revents resection of the vital peripheral cornealfibers that contribute greatly to the biomechanicalstrength of the cornea M oves the hinge peripherally to maximize stromalbed exposure for full delivery of excimer ablationElliptical FlapRound Flap A llows use of a wider hinge angle to createflap stabilityIntraLase FS Laser (9x)IntraLase FS Laser (300x)Inverted Bevel-In Side CutZiemer FEMTO LDVLaser (9x)Ziemer FEMTO LDVLaser (300x)Images of the IntraLase FS Laser and Ziemer FEMTO LDV Laser are provided by Dr. Daniel S. Durrie.Inverted bevel-in side cut, customizable to 150 ,promotes flap replacement, positioning and adhesionfor optimal biomechanical stability of the post-LASIKcornea.150 Inverted Side Cut Option to 150

The iLASIK SolutionAdvanced Technology that Delivers Personal Best VisionThe iLASIK Solution, available exclusively from AMO, is the combination of IntraLase and AdvancedCustomVue Technologies. This unique blend of technologies sets a new standard for laser vision correction. 20/16 or Better– The exclusive combination of IntraLase and Advanced CustomVue Technologies provides a trulycustomized treatment, capable of producing 20/16 or better vision* Good Enough for NASA and Your Patients– NASA astronauts and U.S. fighter pilots can have laser vision correction surgery today because ofthe exclusive, validated safety and precision performance of iLASIK Technologies Leading Innovation– With over 20 years of innovation and more than 10 millionprocedures worldwide, iLASIK Technologies are the true industry leaders Physician Confidence– The iLASIK Platform, along with unmatched service and support,gives surgeons the confidence to consistently deliver t

Courtesy of Jason Stahl, MD, Durrie Vision, Overland Park, KS, USA. Enhanced Safety with Unparalleled Uniformity and Precision Flap Creation Safety Advantages3-5 Reduces or eliminates several complications including: Buttonholeflap dehisced and peak force could be or free flaps Irregular flaps Microperforations Decentered flaps Epithelial defects Postoperative Safety .