M-SERIES MHP4-11ELECTRIC HEAT PUMPPACKAGED UNITFORM NO. MHP4-100 (01/2021)MODEL NUMBER GUIDE3 M HP 4 11 18 1 F P 1REVISION CODEFACTORY INSTALLEDELECTRIC HEAT3 3 KW5 5 KW7 7 KW10 10 KWP 208/230 V - 1 PH - 60HZC COIL CORROSION PROTECTION &VENTILATION AIRF VENTILATION AIRM MAGIC-PAKSERIESHP HEAT PUMP / ELECTRICHEATNOMINAL COOLING CAPACITY09 9,000 BTU/HR12 12,000 BTU/HR18 18,000 BTU/HR24 24,000 BTU/HR30 30,000 BTU/HR36 36,000 BTU/HR4 R-410A REFRIGERANT11 11 EER* Check that equipment complies with all applicable building codes, laws, and regulations for its intended use prior to installation.Page 1

MHP4-11M-SERIES CONTENTSAPPLICATIONS.3UNIT APPROVALS.3WARRANTY (RESIDENTIAL AND COMMERCIAL).3STANDARD FEATURES.3OPTIONS & ACCESSORIES.4FACTORY-INSTALLED OPTIONS.4FIELD-INSTALLED ACCESSORIES. 5UNIT ELECTRICAL AND PHYSICAL DATA.6UNIT DIMENSIONS (IN.).7MINIMUM CLEARANCES.8OUTDOOR SOUND RATING & CABINET AIR LEAKAGE.9FACTORY FILTER SIZE (IN.) AND PRESSURE DROP (IN. W.C.).9OPTIONAL VENTILATION AIR CAPABILITY.9WALL SLEEVES & LOUVERS.10SCCR ACCESSORY. 11MOTORIZED VENTILATION DAMPER. 11CRANKCASE HEATER. 11RATED COOLING & HEATING PERFORMANCE. 12EXTENDED HEATING PERFORMANCE DATA. 12COMBINED EXTENDED HEATING PERFORMANCE DATA. 13EXTENDED COOLING PERFORMANCE DATA. 15BLOWER PERFORMANCE. 16- Page 2 -

MHP4-11M-SERIES APPLICATIONS Magic-Pak units are designed for use in STANDARD FEATURESAIRFLOW CHOICE Factory shipped ready for top supply and returnduct connections Field-adaptable free return configuration, whichmay utilize the top or the front as return points Front access panel doubles as cover for topreturn (except 3.0 ton)all multifamily residential and commercialapplications, such as: apartments, condominiums,student housing and senior livingInstallation in conditioned and non-conditionedmechanical spacesUNIT APPROVALSELECTRICAL CONNECTIONS & GAUGE PORTS Line voltage knockouts (two concentric) toaccommodate field required wire size Thermostat connections are located at the topof the cabinet Two gauge ports are located within the lowercompartment of the unit Refer to Unit Dimension figure for additionaldetailsETL (INTERTEK) Design certified by ETL Intertek to latest editionof UL 1995 Certified for the U.S. and Canada Certified for less than 1.4% cabinet air leakageusing ASHRAE Standard 193 Factory-installed electric heaters are ETL listedfor the U.S. and Canada Rated and tested in accordance with DOE testprocedures and Federal Trade Commission (FTC) labeling regulations Rated with a 5kA Short Circuit Current Rating(SCCR) in accordance with RMS Symmetrical perUL 508A Refer to Unit Electrical and Physical Data tablefor additional detailsCABINET Embossed steel cabinet Indoor section of the cabinet insulated with 0.5in. dual density fiberglass insulation Outdoor section of the cabinet insulated with 0.5in. weather-resistant polystyrene insulationINTERNAL FILTER Tool-less filter access Factory-installed 1 in. filter rack with washablefilter Field-provided filters up to MERV 6 can typicallybe installed in the unit’s factory filter location inlieu of washable filter, when proper duct designis applied If a higher resistance filter is field installed in theunit, the added resistance must be included in theexternal static pressure and must not exceed 0.5in. w.c. including ductwork Refer to Factory Filter Size and Pressure Dropand Blower Performance tables for additionaldetailsAHRI/DOE Certified to AHRI Standard 390 for singlepackage vertical units (SPVAC); refer to the AHRIDirectory for AHRI certificates Cooling system rated in accordance withDepartment of Energy (DOE) test proceduresCORROSION PROTECTION Coating is specifically designed for use on HVACtype coils and demonstrates 6800 hours of SeaWater Acetic Acid Testing (SWAAT) per ASTMG85:A3SOUND RATING Outdoor sound level measurements tested perANSI/AHRI Standard 270 Refer to Outdoor Sound Rating & Cabinet AirLeakage table for additional detailsVENTILATION AIR Units are outfitted with ventilation air openingsand are shipped with the openings sealed Refer to Optional Ventilation Air Capability tableand Optional Field-Installed Accessories sectionfor additional details Check that equipment complies with allapplicable building codes, laws, and regulationsfor its intended use prior to installationLOUVER - PAINT SPECS Standard and impact-resistant louvers meetAAMA 2605 specificationsWARRANTY(RESIDENTIAL AND COMMERCIAL)COMPRESSOR Five (5) years limited parts warrantyALL OTHER COVERED COMPONENTS Refer to Equipment Limited Warranty foradditional details- Page 3 -

MHP4-11M-SERIES REFRIGERATION SYSTEM Factory charged with R-410A refrigerant Factory sealed and tested Refer to Unit Electrical and Physical Data tablefor additional detailsElectronic Blower Control Dedicated blower speed taps for continuous fan,cooling, and heating operation are programmedfor optimal airflow and controlled by 24Vthermostat signals Blower speed adjustment is easily accomplishedby speed tap selection Fixed blower delays have been selected toenhance comfort Refer to Blower Performance tables for additionaldetailsIndoor and Outdoor Coils Copper tube with aluminum fin coilsHigh Pressure Switch Shuts off unit if abnormal operating conditionscause the refrigerant discharge pressure to riseabove acceptable levelsOUTDOOR COIL FAN Heavy duty, fully enclosed and weatherproof Aluminum fan bladesLow Pressure Switch Provides loss of charge protection by shuttingoff unit if refrigerant liquid pressure falls belowacceptable levelsCONDENSATE MANAGEMENTPrimary Drain Pan Antimicrobial protection: drain pan is injectedwith an antibacterial agent that destabilizes themembrane of microorganism cells, disruptingthe cellular function of odor-causing mold andbacteria so that they can no longer grow orreproduceReversing Valve Reverses the direction of refrigerant flow withinthe unit’s refrigeration circuit, to change betweencooling and heating operation. Reverses refrigerant flow direction during heatpump defrost cycles to clear outdoor coil of frostbuildup.Overflow Protection Indoor drain pan overflow switch, which monitorsthe condensate level in primary drain pan Prevents units from operating if drain clogs andwater is sensedDefrost Control Factory mounted sensor determines whendefrost cycle starts and ends Anti-short cycle, timed-off control is incorporatedin the control boardSecondary Drain Pan Polypropylene wall sleeve base is specificallydesigned to direct rain water out of the buildingand in the event of any restriction in the primarydrain will act as a redundant overflow protectionTRANSFORMER Rated for 40VA Factory wired for 230/240V power supply, andincludes field selectable terminal for 208V Converts line voltage to 24V for the thermostatand control circuits within the unitOPTIONS & ACCESSORIESSUPPLY AIR BLOWERECM Constant Torque Blower Motor Electrically efficient motor for reduced electricalconsumption Motor provides specified air volume at 0.1 in. - 0.5in. w.c. external static pressure Motor is resiliently mounted for quiet operation Blower assembly is easily removed for servicing Refer to Blower Performance tables for additionaldetailsFACTORY-INSTALLED OPTIONSELECTRIC HEAT Mounted internal to unit cabinet Multiple kW sizes available; must specify theelectric heating element size (3kW to 10kW) Optional two stage electric heat wiring on 7 &10kW. In order to utilize this option, it will requirea thermostat with single stage cooling and twostage heating Compatible with 208V, 230V and 240V Helix wound nichrome heating elements exposeddirectly into the air stream resulting in instantheat transfer and low element temperatures Cutoff limit control provides positive protectionin case of excessive temperatures Refer to Rated Cooling & Heating Performancetable for additional details- Page 4 -

MHP4-11M-SERIES SHORT CIRCUIT CURRENT RATING KIT (ASCCR) Provides 200kA of SCCR protection Refer to SCCR Accessory table for additionaldetailsCORROSION PROTECTION Epoxy coated indoor and outdoor coilsFIELD-INSTALLED ACCESSORIESFILTERS Field-supplied MERV 6 filters (as required byASHRAE 62.2) can typically be applied at theunit’s factory filter locationWALL SLEEVES & LOUVERS Units must be installed with approved wall sleeveand louver accessories for safe operation and arerequired for all new construction installationsVENTILATION DAMPERS Optional field-installed Check that the equipment complies with allapplicable building codes, laws, and regulationsfor its intended use prior to installationWALL SLEEVES (ASLEEVE) Penetrates the building envelope and creates apath for condenser air intake and exhaust Provides a sealed connection to the unit and asecure attachment foundation for the louvers Larger height wall sleeves may be used onsmaller tonnage equipment to maintain a uniformwall opening on the building façade Available in 6 in. to 12 in. depthsMotorized Damper w/ Controller Utilizes a ventilation air control module thatis field programmable to assist with meetingASHRAE 62.2 requirements Once programmed with values for ventilationair amounts, the control module opens thedamper in response to thermostat inputs andmonitors the run time Upon meeting the ventilation air needs, thecontrol module will close the damper until thestart of the next cycle If, during an observation period it is determinedthat thermostat operation alone may notprovide the desired ventilation air, the controlmodule can independently operate the unit’sindoor blower, in continuous fan mode, andopen the damper to aid in providing ventilationair needsWALL SLEEVE EXTENSION (ASLEEVEXT4) Option provides an additional 4 in. of depth tothe wall sleeve, for a maximum depth of 16 in.LOUVERSPolypropylene Louvers (ALVRP) Constructed from durable, corrosion-resistantplastic Available in four standard colorsAluminum Louvers (ALVRAL) Constructed with 6063-T6 grade aluminum Available in anodized clear coat, primer (to bepainted in the field), standard paint colors andcustom colors with paint matching*Motorized Damper w/ Field-Supplied Relay Opens ventilation air damper during indoorblower operation and closes during blower offperiods Requires field-supplied and installed currentsensing relay to detect indoor blower operationImpact-Resistant Aluminum Louvers (ALVRALC) 29” and 33” impact-resistant louvers are impactand wind load certified up to 186 MPH, riskcategories III and IV, and wind exposures C and D(FBC Notice of Acceptance number 18-0522.03) Constructed with 6063-T6 grade aluminum Available in anodized clear coat, primer (to bepainted in the field), standard paint colors andcustom colors with paint matching*THERMOSTAT Required for all installations (field-supplied) Units are individually controlled with conventional24V thermostat Thermostat must be capable of: Single stage cooling, single stage heat pumpoperation (compressor heating), and singlestage auxiliary heat (3 and 5 kW) Single stage cooling, single stage heat pumpoperation (compressor heating), and twostage auxiliary heat (7 and 10 kW) Refer to Unit Electrical and Physical Data table

using ASHRAE Standard 193 Factory-installed electric heaters are ETL listed for the U.S. and Canada Rated and tested in accordance with DOE test procedures and Federal Trade Commission (FTC) labeling regulations Rated with a 5kA Short Circuit Current Rating (SCCR) in accordance with RMS Symmetrical per UL 508A Refer to Unit Electrical and Physical Data table for additional .