HPE ProLiant DL380 Gen10 Server User Guide - CNET Content

Transcription

HPE ProLiant DL380 Gen10 Server UserGuideAbstractThis document is for the person who installs, administers, and troubleshoots servers and storagesystems. Hewlett Packard Enterprise assumes you are qualified in the servicing of computerequipment and trained in recognizing hazards in products with hazardous energy levels.Part Number: 868990-003Published: August 2018Edition: 3

Copyright 2018, Hewlett Packard Enterprise Development LPNoticesThe information contained herein is subject to change without notice. The only warranties for Hewlett PackardEnterprise products and services are set forth in the express warranty statements accompanying suchproducts and services. Nothing herein should be construed as constituting an additional warranty. HewlettPackard Enterprise shall not be liable for technical or editorial errors or omissions contained herein.Confidential computer software. Valid license from Hewlett Packard Enterprise required for possession, use,or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer SoftwareDocumentation, and Technical Data for Commercial Items are licensed to the U.S. Government undervendor's standard commercial license.Links to third-party websites take you outside the Hewlett Packard Enterprise website. Hewlett PackardEnterprise has no control over and is not responsible for information outside the Hewlett Packard Enterprisewebsite.

ContentsComponent identification. 8Front panel components.8Front panel LEDs and buttons.9UID button functionality.13Front panel LED power fault codes. 13Systems Insight Display LEDs.13Systems Insight Display combined LED descriptions.14Rear panel components. 16Rear panel LEDs. 17System board components.18System maintenance switch descriptions. 19DIMM label identification.20DIMM slot locations. 21NVDIMM identification. 21NVDIMM 2D Data Matrix barcode. 22NVDIMM LED identification. 23NVDIMM-N LED combinations. 23NVDIMM Function LED patterns.23Processor, heatsink, and socket components. 24Drives. 24SAS/SATA drive components and LEDs.25NVMe SSD LED definitions. 26uFF drive components and LEDs. 27Fan bay numbering.28Drive box identification. 29Drive bay numbering. 30Drive bay numbering: Smart Array controller.31Drive bay numbering: SAS expander. 32Drive bay numbering: NVMe drives. 35uFF drive bay numbering.35Riser components.36HPE Flex Slot Power Supply with Integrated Battery Backup Unit components and LED. 40Checking the battery backup charge level.41HPE 12G SAS Expander Card port numbering.42HPE Smart Array P824i-p MR Gen10 Controller.42Operations.44Power up the server. 44Power down the server.44Extend the server from the rack. 44Extending the server from the rack.45Removing the server from the rack. 46Secure cables using the cable management arm. 46Remove the access panel. 47Installing the access panel. 48Removing the fan cage.48Installing the fan cage.49Removing the air baffle or midplane drive cage. 50Installing the air baffle.51Contents3

Removing a riser cage.52Removing a riser slot blank. 53Removing the hard drive blank.54Releasing the cable management arm .54Accessing the Systems Insight Display. 55Setup.56HPE support services. 56Set up the server. 56Operational requirements. 60Space and airflow requirements. 60Temperature requirements.60Power requirements.61Electrical grounding requirements. 61Connecting a DC power cable to a DC power source. 61Server warnings and cautions. 63Rack warnings. 63Electrostatic discharge.64Server box contents.64Installing hardware options . 65POST screen options.65Installing or deploying an operating system.65Registering the server.65Hardware options installation. 66Product QuickSpecs. 66Introduction.66Installing a fan filter into the security bezel.66Installing the bezel and bezel lock.67Power supply options. 67Hot-plug power supply calculations. 67Installing a redundant hot-plug power supply. 67Drive options.68Drive guidelines. 69Supported drive carriers. 69Installing a hot-plug SAS or SATA drive.69Installing an NVMe drive.70Installing a uFF drive and SCM drive carrier. 71Installing an M.2 drive.72Fan options.73Installing high-performance fans.74Memory options. 76DIMM and NVDIMM population information. 76HPE SmartMemory speed information. 76Installing a DIMM. 76HPE 16GB NVDIMM option.77Server requirements for NVDIMM support.78Installing an NVDIMM. 78Configuring the server for NVDIMMs . 80NVDIMM sanitization. 80NVDIMM relocation guidelines.81HPE Scalable Persistent Memory (CTO only). 81Controller options. 82Installing a storage controller.824Contents

Installing an HPE Smart Array P824i-p MR Gen10 controller in a configured server.83Array and controller configuration. 84Installing a Universal Media Bay. 85Drive cage options.87Installing a front 8NVMe SSD Express Bay drive cage. 87Installing a front 6SFF SAS/SATA 2NVMe Premium drive cage. 89Installing airflow labels. 91Installing a front 8SFF SAS/SATA drive cage in box 1. 92Installing a front 8SFF SAS/SATA drive cage in box 2. 94Installing a front 2SFF NVMe/SAS/SATA Premium drive cage.96Installing a midplane 4LFF SAS/SATA drive cage.99Installing a rear 2SFF SAS/SATA drive cage in the primary or secondary riser. 102Installing a rear 2SFF SAS/SATA drive cage over the power supplies.104Installing a rear 3LFF SAS/SATA drive cage. 107Riser and riser cage options.108Installing primary and secondary risers. 109Installing tertiary risers. 110Installing a secondary riser cage.111Installing a tertiary riser cage. 112Installing the 2NVMe slimSAS riser option. 115Installing the 8NVMe slimSAS riser option. 116Expansion slots.117Supported PCIe form factors. 117Installing expansion boards. 118Installing a 12G SAS Expander Card. 120Installing a GPU card.123Installing an intrusion detection switch. 127Installing a Smart Storage Battery.128Installing a rear serial port interface. 129Installing a Systems Insight Display. 132Installing a FlexibleLOM adapter. 134Installing a 1U or high-performance heatsink. 136Installing a processor.138HPE Trusted Platform Module 2.0 Gen10 option. 140Overview.140HPE Trusted Platform Module 2.0 Guidelines. 141Installing and enabling the HPE TPM 2.0 Gen10 Kit. 141Installing the Trusted Platform Module board. 141Enabling the Trusted Platform Module.144Retaining the recovery key/password. 146Cabling.147HPE ProLiant Gen10 DL Servers Storage Cabling Guidelines. 147Cabling diagrams.147Cable routing: Front 2SFF drive option for SFF.150Cable routing: Front 2SFF drive option for LFF. 150Cable routing: Front 2SFF drive options (3 position cable). 151Cable routing: Front 8SFF drive options.152Cable routing: Front 8SFF NVMe/SAS premium drive option. 154Cable routing: Front 8SFF NVMe drive options.154Cable routing: Front 2SFF NVMe drive option for SFF.156Cable routing: Front 2SFF NVMe drive option for LFF. 157Cable routing: Midplane 4LFF drive option.157Cable routing: Rear 3LFF drive option.158Cable routing: Rear 2SFF drive options. 158Contents5

Cable routing: HPE 12G SAS Expander to a controller.159Cable routing: Smart Array P824i-P Controller.160Cable routing: Systems Insight Display. 162Software and configuration utilities.164Server mode. 164Product QuickSpecs. 164Active Health System Viewer. 164Active Health System.165Active Health System data collection.165Active Health System Log.165HPE iLO 5.165iLO Federation. 166iLO Service Port.166iLO RESTful API. 167RESTful Interface Tool.167iLO Amplifier Pack. 167Integrated Management Log. 167Intelligent Provisioning.168Intelligent Provisioning operation.168Management Security.169Scripting Toolkit for Windows and Linux. 169UEFI System Utilities.169Selecting the boot mode . 170Secure Boot. 170Launching the Embedded UEFI Shell .171HPE Smart Storage Administrator.172HPE MR Storage Administrator.172StorCLI. 173USB support. 173External USB functionality. 173Redundant ROM support.173Safety and security benefits.173Keeping the system current.173Updating firmware or system ROM.173Service Pack for ProLiant. 174Updating firmware from the System Utilities . 175Updating the firmware from the UEFI Embedded Shell . 176Online Flash components. 176Drivers. 176Software and firmware.176Operating system version support. 177HPE Pointnext Portfolio. 177Proactive notifications.177Troubleshooting.178NMI functionality. 178Troubleshooting resources. 178Battery replacement. 179Safety, warranty, and regulatory information.1816Contents

Safety and regulatory compliance. 181Warranty information. 181Regulatory information. 181Belarus Kazakhstan Russia marking. 181Turkey RoHS material content declaration. 182Ukraine RoHS material content declaration.182Specifications. 183Environmental specifications. 183Mechanical specifications.183Power supply specifications. 184HPE 500W Flex Slot Platinum Hot-plug Low Halogen Power Supply. 185HPE 800W Flex Slot Platinum Hot-plug Low Halogen Power Supply. 186HPE 800W Flex Slot Titanium Hot-plug Low Halogen Power Supply. 186HPE 800W Flex Slot Universal Hot-plug Low Halogen Power Supply. 187HPE 800W Flex Slot -48VDC Hot-plug Low Halogen Power Supply. 188HPE 800W Flex Slot Scalable Persistent Memory Power Supply. 189HPE 1600W Flex Slot Platinum Hot-plug Low Halogen Power Supply. 190Support and other resources. 191Accessing Hewlett Packard Enterprise Support. 191Accessing updates. 191Customer self repair. 192Remote support. 192Warranty information. 192Regulatory information.

HPE ProLiant DL380 Gen10 Server User Guide Part Number: 868990-003 Published: August 2018 Edition: 3 Abstract This document is for the person who installs, administers, and troubleshoots servers and storage