COMMUNICATIONS INFRASTRUCTURE STANDARDS &

Transcription

COMMUNICATIONSINFRASTRUCTURESTANDARDS &SPECIFICATIONS3.0This document is specific to Information Management and Information Technology Communications Infrastructure Standardsand Specifications at all of the Health Authorities (IHA) sites and is to be used in conjunction with Division 26, 27, and 28 ofany project with an IMIT infrastructure impact. This document contains unpublished, confidential and proprietary information ofIHA. Any unauthorized use, reproduction, or transfer of this document without the express written consent of the AuthoritiesFacilities Project Coordinator is strictly prohibited.RELEASE DATE: SEPTEMBER 2017

This page intentionally left blank

Version ControlThe contents of this document cannot be modified without prior written consent from the original Contributors2017 –09-01:Version 3.0 Updates 2015–03-01Version 2.1 Updates 2014 -10-10:Section 3.2:Section 4.2:Section 4.7.4:Section 4.9:Hoarding removed as it is included in the Infection Control and Prevention Manual.Modified as ND&I only required on completely new systems.Specialized TV Telecommunication Outlet information added.Modified to included pathway for TV control.Version 2.0 Updates 2013-10-07:Name change to Communications Infrastructure Standards & Specifications.Changed all references from TE Connectivity to AMP NetconnectUpdated all sections to reflect changes in technology since last revision.Rack layout added for stacked design.More details included for Firestopping and Meeting/Conference Rooms, including DIRTT.Added information to Appendices.All references hyperlinked in document for ease of electronic navigationSection 1.2: Focuses on new builds with the use of CAT6A copper and OM4 fiber.Section 2.1: Reworded for better clarificationSection 4.2: Reworded for better clarificationSection 4.6.1: Max backbone distance chart and star topology diagram removed as not neededSection 4.7: Reorganized for better flow and readabilitySection 4.8: Pathway Requirements addedSection 4.9 -4.11: Reworded for better clarificationSection 4.12: Part numbers updated to reflect CAT6A technologySection 8: Height of outlets raised to 450 mm AFF from 350 mm AFF, and in-slab floor conduit added.Appendix 4: Product Specification Sheets added. (updated Jan 23, 2015)Version 1.0 Updates Distributed to replace the IHA IMIT Cabling Specification with updates of standardsContributorsThe following subject matter experts formed the committee for content and change management of this document. Anyrevisions made to the latest release as indicated above must be approved by the Contributors: Authority IMIT Facilities Project Coordinator (IMITFPC)Authority IMIT Networks and Telecommunications Department (NTS)Authority IMIT Video Conferencing AnalystCopyright 2017 Interior Health Authority505 Doyle Avenue,Kelowna, BC, CanadaV1Y 0C5Email: IMITFPC@interiorhealth.caWebsite: http://www.interiorhealth.ca

COMMUNICATIONS INFRASTRUCTURE STANDARDS & SPECIFICATIONS 3.01 TABLE OF CONTENTS1INTRODUCTION . 11.1 Purpose . 11.2 Scope. 11.3 Work Included . 21.4 Referenced Codes & Standards . 22DEMOLITION REQUIREMENTS . 32.1 Demolition . 32.2 Disposal . 433.13.23.34DUST CONTAINMENT AND ACCESS . 4General . 4Hoarding . 5Cleaning. 5TELECOMMUNICATIONS SYSTEM REQUIREMENTS . 54.1 Purpose . 54.2 Basic Communications Requirements . 54.3 Administration Requirements . 54.4 Contractor’s Responsibility . 64.5 Communication Equipment Rooms . 74.5.1 Communication Rooms . 74.5.2 Entrance Facility (EF). 114.5.3 Main Cross Connect (MCC) and Back-up Cross Connect (BCC) . 114.5.4 Telecommunications Rooms (TR) . 124.6 Backbone and Riser Cabling Requirements . 134.6.1 General Backbone Cabling Requirements . 134.6.2 Optical Fiber Data Backbone Requirements . 134.6.3 Analog Backbone Requirements . 144.7 Horizontal Cabling Requirements . 144.7.1 Wire Product Specifications . 144.7.2 Modular Jacks . 144.7.3 Face/Wall Plates . 154.7.4 Telecommunications Outlets (TO). 154.8 Pathway Requirements . 154.9 Nurse Call Systems . 164.10 Security, Video IP Surveillance Systems . 174.11 Wireless Infrastructure . 174.12 Patient Infotainment Systems . 174.13 Patch and Interconnection Cabling Requirements . 174.13.1Horizontal Data Cross-Connect . 174.13.2Voice/Data BIX Cross-connect . 174.14 Fiber Termination . 18

4.15 Labelling . 184.15.1General. 184.15.2Panel Labelling . 194.15.3Horizontal Cables Labelling and Termination . 194.15.4Telecommunications Outlet Labelling. 194.15.5Backbone Cable Labelling. 204.15.6Patch Cable Labelling . 204.16 Low Voltage Certification Testing . 204.17 Telecommunications Infrastructure Acceptance . 204.17.1Inspections . 204.17.2Final Inspection . 204.17.3Test Verification. 204.17.4System Performance . 214.17.5Final Acceptance . 214.18 Warranty and Services. 214.18.1General. 214.18.2Installation Warranty. 215ELECTRICAL SPECIFICATIONS . 215.1 Grounding and Bonding . 215.2 Product Specifications . 215.3 Ground System Installation . 2266.16.26.3FIRESTOP SYSTEMS. 22General . 22Product Specifications . 22Firestop System Installation . 237COMMISSIONING AND SYSTEMS INTEGRATION . 237.1 Acceptance . 238A/V MEETING AND CONFERENCE ROOM STANDARDS . 238.1 Telehealth Rooms . 238.2 Small Room . 248.3 Medium Room. 258.4 Large Room (with wall mounted television) . 268.5 Large Room (with ceiling mounted projector) . 2799.19.2CABLE MANAGEMENT AND DESKTOP PLACEMENT GUIDELINES . 28Communication Room Guidelines . 28Desktop Guidelines . 2810 FINAL ACCEPTANCE . 2810.1 System As-Built Drawings. 2810.2 Sign off.

This document is specific to Information Management and Information Technology Communications Infrastructure Standards and Specifications at all of the Health Authorities (IHA) sites and is to be used in conjunction with Division 26, 27, and 28 of any project with an IMIT infrastructure impact. This document contains unpublished, confidential and .