375 FieldCommunicator - AAATesters

Transcription

Provided by www.AAATesters.comProduct Data SheetD351019X012/00813-0100-4276Bulletin 62.1: CommunicatorJune 2003375 Field Communicator375 Field Communicator Universal – HART andFOUNDATION TM fieldbus User upgradeable Intrinsically safe Rugged and reliable Interfaces with AMSThe 375 Field Communicator is designed to supportall HART and all FOUNDATION fieldbus devices from all vendors.IntroductionThe 375 Field Communicator isthe new standard in handheldcommunicator that supportsall their fieldbus devices.communicators. Built on overThe result is the universal,ten years of experience with theuser upgradeable, intrinsically275 HART Communicator, usersafe, rugged and reliablerequirements drove the features of375 Field Communicator.this next generation communicator.HART users worldwide told ushow to make a better communicator.Fieldbus users said they wantedwww.fieldcommunicator.coma portable intrinsically safe

Product Data Sheet375 Field CommunicatorJune 2003We made sure that the weight wasevenly distributed for comfortableone-handed operation in the field. It is loaded!The 375 Field Communicator hasa processor that is 20 times fasterthan the 275. It features 32MB ofapplication memory, 64 times morethan the 275 HART Communicator.The Configuration ExpansionModule holds hundreds of deviceconfigurations, and it is externallyaccessible. Enhancements in thebattery pack allow a full rechargein 2 hours, 8 times faster than the275 HART Communicator. Easy Upgrade keeps yourcommunicator current.A fold-away stand provides the correct viewing angle on the bench,and flips up to a locked position for secure hanging in the plant.If that’s not enough to getyour attention, the 375 FieldCommunicator is also userSee the difference.Product Description Building on the experience with theThe 375 Field Communicator runsproven 275 HART Communicator,on Windows CE, a robust, real-time,the 375 Field Communicatoroperating system. The display isincludes enhancements designed70% larger than that of the 275to simplify your work in the field.HART Communicator and usesWe designed the 375 Fieldtransflective technology, making itCommunicator user interfaceeasy to read in both bright sunlightaround the 275, leveraging theand in normal lighting. To make surenavigation features users told uswe covered all conditions, we addedthey liked. Then we added powerfula multi-level backlight, allowing thefeatures including a much largerdisplay to be viewed in those areastouch screen, HART Revision 6of your plant with dim light. Thesupport, and the ability to upgradetouch sensitive display and largeyour 375 Field Communicatorphysical navigation buttons provideonsite using the Internet.for efficient use both on the benchand in the field.Page 2upgradeable via the Internet.This means it is no longernecessary to send yourcommunicator anywhere tohave new device drivers added.

Product Data Sheet375 Field CommunicatorJune 2003Designed not only for use on the bench, the 375 Field Communicatorenables you to do those tasks that just have to be done in the field.Universal – HART andin your plant. Use it to performWith over 600 different HART andFOUNDATION fieldbusdiagnostics for effective start-upFOUNDATION fieldbus devices fromThe 375 Field Communicator isand troubleshooting of FOUNDATIONmore than 100 different vendors,designed to support all HARTfieldbus segments. Create a qualityhaving a single field communicatorand FOUNDATION fieldbus devices.segment by diagnosing the networkthat works with everything is a bigIf you are familiar with the 275DC voltage and average noise.help. So, grab the 375 FieldHART Communicator, used inDetect power supply problemsCommunicator and go!thousands of plants worldwideby monitoring low frequency noisefor more than ten years, you willon a segment. Locate incorrectappreciate universal HARTterminations and faulty devices bysupport in a single intrinsicallydiagnosing the communicationssafe handheld communicator.signal level. No longer do you need The 375 Field Communicatorcan also be used to configure allthe FOUNDATION fieldbus devicesPage 3to drag a laptop computer out intothe plant to communicate with yourFOUNDATION fieldbus devices.

Product Data Sheet375 Field CommunicatorJune 2003Easy Upgrade allows communication between the 375 Field Communicator and a PC using IrDA.The IrDA port enables transfer of configuration data between the 375 and AMS as well as upgradingo f new Device Descriptions and functionality.As new HART and FOUNDATIONyour communicator to a serviceNew HART and FOUNDATION fieldbusfieldbus DD’s become available,center to have new DD’s ordevices, as well as functionaldownload them from the Internetsoftware updates added.updates to existing devices areand upgrade your 375 FieldNo longer is it necessary tointroduced continually by deviceCommunicator.be without your communicatorvendors. Keeping up-to-date withIn addition, as functionalwhile you wait for upgrades.the required Device Descriptionenhancements to the 375Easy Upgrade lets you updatedrivers for all the devices in yourHART and FOUNDATION fieldbusyour own 375 Field Communicator.plant can be a real challenge. Now,applications become available,On your site, within your control,with the Easy Upgrade option,download software updates fromwhen it’s convenient for you.keeping your communicatorthe Internet and upgrade yourupdated with the most current375 Field Communicator. NoDevice Descriptions (DD’s) is easy.longer is it necessary to send User upgradeablePage 4

Product Data Sheet375 Field CommunicatorJune 2003Even the battery pack is approvedAs for reliable, when was the lastThe 375 Field Communicator meetsfor installation in hazardous areas.time you had to send your 275the Intrinsic Safety requirementsThe 375 Field Communicator isHART Communicator in for repair?of the listed regulatory agenciesdesigned for use in areas whereThat’s exactly the kind of reliabilityand standards. All of the availablelaptops shouldn’t go.we’ve built into the 375. The 375 Intrinsically Safe.Hazardous Locations approvals Rugged and Reliable.are provided in a single modelIt’s called ‘Field Communicator’ foroption (see Ordering Information).a reason. Some tasks just have to– CENELEC/ATEXbe performed at the device. The– Factory Mutual (FM)375 Field Communicator is designed– Canadian Standards Association (CSA)for tough use in your plant or mill.– FISCOField Communicator is designed,manufactured and tested tospecifications that are evenmore demanding. The 375Field Communicator is designedto go wherever you have to goto get the job done.Its large keys and physicalnavigation buttons allow for onehanded operation, even with yourwork gloves on. The rugged displayis designed to take the knocks andshocks from normal use in the plant.SpecificationsPROCESSOR AND MEMORYSPECIFICATIONSMicroprocessor 80 MHz Hitachi SH3POWER SUPPLY SPECIFICATIONSBattery Pack Rechargeable NiMH batteriesBattery Operating TimeUp to ten hours depending on usageMemory Internal Flash 32 MB System Card 128 MB or higher secure digital card RAM 32 MBExpansion Module 32 MB or higher secure digital cardPHYSICAL SPECIFICATIONSWeight Approximately 2 lb. (0.9kg) with batteryDisplay 1/4 VGA (240 by 320 pixels)monochrome 3.8” (9.6 cm) transflectivedisplay with touch screen Anti-glare coatedKeypad 25 keys including 4 action keys,12 alphanumeric keys, 4 programmablefunction keys, on/off, and 4 cursor-control(arrow) keys; membrane design withtactile feedbackPage 5Battery Charger OptionsInput voltage 85-240 VAC, 50/60 Hz Cables included with U.S., Europeanand U.K. plugsONNECTIONCONNECTION SPECIFICATIONSBattery Charger Mini DIN 4-pin jackHART and Fieldbus Three 4mm banana plugs (one commonto HART and FOUNDATION fieldbus)IrDA Port IrDA (Infrared Data Access) portsupporting up to 115 Kbps 15 degrees recommended maximumangle from center line Approximately 12” (30 cm)recommended maximum distanceENVIRONMENTAL SPECIFICATIONSUsage -10 C (14 F ) to 50 C (122 F ) 0% to 95% RH (non-condensing)for 0 C (32 F ) to 50 C (122 F )Charge0 C (32 F ) to 40 C (104 F ) Storage-20 C (-4 F ) to 55 C (131 F )with batteries Storage Without Batteries-20 C (-4 F ) to 60 C (140 F ) Enclosure RatingIP51 (from front) ShockTested to survive a 1-meterdrop test onto concrete EASY UPGRADE REQUIREMENTSUsage PC with internet access CD Rom drive IrDA port (or adapter) Windows 2000 or XP

Product Data Sheet375 Field CommunicatorJune 2003 Interfaces with AMS.The 375 Field Communicator is fullycompatible with AMS, the industrystandard for asset managementsoftware. In fact, Control MagazineAMS allows you to configure,Configuration Expansion Modulestreamline calibration, documentstores hundreds of deviceand troubleshoot HART andconfigurations safely in yourFOUNDATION fieldbus devices.375 Field Communicator.AMS uses the intelligence fromfield devices to create a predictivemaintenance environment.readers selected AMS as the #1Transfer device configurationCalibration Software package fordata via the infrared port on the3 years in a row.375 Field Communicator and375 Field Communicator out toThe Configuration ExpansionModule safely stores hundredso f device configurations.the field to configure or updateTogether, the 375 Fieldone or many devices. Save deviceCommunicator and AMS enableconfigurations in your 375 Fieldyou to more efficiently manageCommunicator for safe storage orall of your devices, the assetstransfer to AMS. The optionalthat are the foundation ofAMS on your PC. Carry youryour process.Page 6

Product Data Sheet375 Field CommunicatorJune 2003375 Field Communicator Spare Parts ListDescriptionPart NumberRuggedized 250 Ohm Load Resistor00275-0096-0001Rechargeable NiMH Battery Pack with Accessory Case00375-0002-0011Power Supply/Charger(90-240 VAC, 50/60Hz, US/UK/EU connection types included) 00375-0003-0011Lead Set with connectors00375-0004-0001Mounting Straps00375-0005-0002Carrying Case (with straps)00375-0005-0003Accessory Case (clips to Carrying Case)00375-0005-0004Stylus (pack of 5)00375-0006-0001IRDA to USB Adapter (1)00375-0015-0002Expansion Port Plug00375-0031-0001System Card - HART and FOUNDATION fieldbus00375-0042-0002System Card - HART with Easy Upgrade Option (2)00375-0042-0003System Card - HART and FOUNDATION fieldbuswith Easy Upgrade Option (2)00375-0042-0004Configuration Expansion Module00375-0043-0001Stand and Utility Plate00375-0044-0001Getting Started Guide00375-0045-0001User's Manual00375-0047-0001Resource CD (3)00375-0049-0001(1)For use with AMS/375 Interface or 375 Easy Upgrade Programming Utility.(2)Includes unlimited upgrades to System Card for 3 year period.(3)Contains 375 Programming Utility and System Software/DD database.Page 7

Product Data Sheet375 Field CommunicatorJune 2003375 Field Communicator Ordering InformationModel375CodeHFCodeRCode1Product DescriptionField Communicator (1)Communication ProtocolHARTHART and FOUNDATION fieldbusBattery TypeRechargeable NiMH Battery PackPower Supply/RechargerPower Supply/Recharger(90/240 VAC, 50/60Hz, US/UK/EU connection types included)9None (2)CodeLanguageEEnglish (standard)CodeApproval CertificationsKLCENELEC/ATEX, FM, CSA Intrinsically Safe(includes FISCO as applicable)NANo ApprovalCodeEasy Upgrade (3)UEasy Upgrade Option(includes unlimited upgrades to System Card for 3 year period)9Not IncludedCodeOptionsSpare Battery PackBSpare Rechargeable NiMH Battery Pack (4)Expansion ModuleCConfiguration Expansion Module (5)Typical Model Number: 375 H R 1 E KL U(1)(2)(3)(4)(5)Base Model 375 includes Field Communicator Unit, System Card,Leadset with Connectors, Carrying Case, Getting Started Guide,User's Manual, 375 Resource CD, Stylus and Straps.This option should only be considered if the user already has a 375 PowerSupply/Charger. Note: Only 375 Power Supply/Chargers may be usedwith the 375 Battery Pack.The Easy Upgrade capability allows the user to add new System Applicationsoftware and Device Descriptions (DD’s) to the 375. To upgrade without thisfeature, the System Card must be sent a Service Center.A fully charged battery pack is capable of delivering power for 8 hoursof typical field use. If requirements exceed this specification, a secondbattery pack is recommended.The 375 is capable of storing a total of 25 configurations. For increasedstorage capacity, use the Configuration Expansion Module which is capableof storing in excess of 500 configurations.Emerson Process ManagementAsset Optimization Division12001 Technology DriveEden Prairie, MN 55344 USAT 1(512) 832-3235F 1(952) 828-3033www.fieldcommunicator.com 2003, Emerson Process Management.The contents of this publication are presented for informational purposes only, and while every efforthas been made to ensure their accuracy, they are not to be construed as warranties or guarantees,express or implied, regarding the products or services described herein or their use or applicability.All sales are governed by our terms and conditions, which are available on request. We reserve theright to modify or improve the designs or specifications of our products at any time without notice.All rights reserved. AMS is a mark of one of the Emerson Process Management group of companies.The Emerson logo is a trademark and service mark of Emerson Electric Company.All other marks are the property of their respective owners.

the Internet and upgrade your 375 Field Communicator.No longer is it necessary to send your communicator to a service center to have new DD's or software updates added. No longer is it necessary to be without your communicator while you wait for upgrades. Easy Upgradelets you update your own 375 Field Communicator. On your site,within your .